Data Sheet ADuM3200/ADuM3201
Rev. F | Page 13 of 24
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval for a 560 V peak working voltage.
Table 28.
Description Test Conditions/Comments Symbol Characteristic Unit
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms I to IV
For Rated Mains Voltage ≤ 300 V rms I to III
For Rated Mains Voltage ≤ 400 V rms I to II
Pollution Degree per DIN VDE 0110, Table 1
2
Maximum Working Insulation Voltage V
IORM
560 V peak
Input-to-Output Test Voltage, Method B1 V
IORM
× 1.875 = V
PR
, 100% production test, t
m
= 1 sec,
partial discharge < 5 pC
V
PR
1050 V peak
Input-to-Output Test Voltage, Method A V
IORM
× 1.6 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC V
PR
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2
and Subgroup 3
V
IORM
× 1.2 = V
PR
, t
m
= 60 sec, partial discharge < 5 pC 672 V peak
Highest Allowable Overvoltage Transient overvoltage, t
TR
= 10 seconds V
TR
4000 V peak
Safety-Limiting Values Maximum value allowed in the event of a failure
(see Figure 3)
Case Temperature T
S
150 °C
Side 1 Current I
S1
160 mA
Side 2 Current I
S2
170 mA
Insulation Resistance at T
S
V
IO
= 500 V R
S
>10
9
Ω
CASE TEMPERATURE (°C)
SAFETY-LIMITING CURRENT (mA)
0
0
200
180
100
80
60
40
20
50 100 150 200
SIDE #1
SIDE #2
120
140
160
05927-003
Figure 3. Thermal Derating Curve, Dependence of Safety-Limiting Values
on Case Temperature, per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 29.
Parameter Symbol Min Max Unit
Operating Temperature T
A
ADuM3200A/ADuM3201A −40 +105 °C
ADuM3200B/ADuM3201B −40 +105 °C
ADuM3200C/ADuM3201C −40 +105 °C
ADuM3200WA/ADuM3201WA −40 +125 °C
ADuM3200WC/ADuM3201WC −40 +125 °C
Supply Voltages
1
V
DD1
, V
DD2
ADuM3200B/ADuM3201B 3.0 5.5 V
ADuM3200C/ADuM3201C 3.0 5.5 V
ADuM3200WA/ADuM3201WA 3.0 5.5 V
ADuM3200WB/ADuM3201WB 3.0 5.5 V
ADuM3200WC/ADuM3201WC 3.0 5.5 V
Maximum Input Signal Rise and
Fall Times
1.0 ms
1
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.