74AC163
4/13
ABSOLUTE MAXIMUM RATINGS
Absolute Maximum Ratings are those values beyond which damage to the device may occur. Functional operation under these conditions is
not implied.
RECOMMENDED OPERATING CONDITIONS
1) V
IN
from 30% to 70% of V
CC
Symbol Parameter Value Unit
V
CC
Supply Voltage
-0.5 to +7 V
V
I
DC Input Voltage -0.5 to V
CC
+ 0.5
V
V
O
DC Output Voltage -0.5 to V
CC
+ 0.5
V
I
IK
DC Input Diode Current
± 20 mA
I
OK
DC Output Diode Current
± 20 mA
I
O
DC Output Current
± 50 mA
I
CC
or I
GND
DC V
CC
or Ground Current
± 300 mA
T
stg
Storage Temperature
-65 to +150 °C
T
L
Lead Temperature (10 sec)
300 °C
Symbol Parameter Value Unit
V
CC
Supply Voltage
2 to 6 V
V
I
Input Voltage 0 to V
CC
V
V
O
Output Voltage 0 to V
CC
V
T
op
Operating Temperature
-55 to 125 °C
dt/dv
Input Rise and Fall Time V
CC
= 3.0, 4.5 or 5.5V (note 1)
8 ns/V
74AC163
5/13
DC SPECIFICATIONS
1) Maximum test duration 2ms, one output loaded at time
2) Incident wave switching is guaranteed on transmission lines with impedances as low as 50
Symbol Parameter
Test Condition Value
Unit
V
CC
(V)
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
V
IH
High Level Input
Voltage
3.0
V
O
= 0.1 V or
V
CC
-0.1V
2.1 1.5 2.1 2.1
V4.5 3.15 2.25 3.15 3.15
5.5 3.85 2.75 3.85 3.85
V
IL
Low Level Input
Voltage
3.0
V
O
= 0.1 V or
V
CC
-0.1V
1.5 0.9 0.9 0.9
V4.5 2.25 1.35 1.35 1.35
5.5 2.75 1.65 1.65 1.65
V
OH
High Level Output
Voltage
3.0
I
O
=-50 µA
2.9 2.99 2.9 2.9
V
4.5
I
O
=-50 µA
4.4 4.49 4.4 4.4
5.5
I
O
=-50 µA
5.4 5.49 5.4 5.4
3.0
I
O
=-12 mA
2.56 2.46 2.4
4.5
I
O
=-24 mA
3.86 3.76 3.7
5.5
I
O
=-24 mA
4.86 4.76 4.7
V
OL
Low Level Output
Voltage
3.0
I
O
=50 µA
0.002 0.1 0.1 0.1
V
4.5
I
O
=50 µA
0.001 0.1 0.1 0.1
5.5
I
O
=50 µA
0.001 0.1 0.1 0.1
3.0
I
O
=12 mA
0.36 0.44 0.5
4.5
I
O
=24 mA
0.36 0.44 0.5
5.5
I
O
=24 mA
0.36 0.44 0.5
I
I
Input Leakage
Current
5.5
V
I
= V
CC
or GND
± 0.1 ± 1 ± 1 µA
I
CC
Quiescent Supply
Current
5.5
V
I
= V
CC
or GND
880160µA
I
OLD
Dynamic Output
Current (note 1, 2)
5.5
V
OLD
= 1.65 V max
75 50 mA
I
OHD
V
OHD
= 3.85 V min
-75 -50 mA
74AC163
6/13
AC ELECTRICAL CHARACTERISTICS (C
L
= 50 pF, R
L
= 500 , Input t
r
= t
f
= 3ns)
(*) Voltage range is 3.3V ± 0.3V
(**) Voltage range is 5.0V ±
0.5V
Symbol Parameter
Test Condition Value
Unit
V
CC
(V)
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
t
PLH
t
PHL
Propagation Delay
Time CLOCK to Q
3.3
(*)
7.0 12.0 13.0 13.0
ns
5.0
(**)
5.0 9.0 9.5 9.5
t
PLH
t
PHL
Propagation Delay
Time CLOCK to
CARRY OUT
3.3
(*)
8.0 14.0 15.0 15.0
ns
5.0
(**)
6.0 10.5 11.5 11.5
t
PLH
t
PHL
Propagation Delay
Time TE to CARRY
OUT
3.3
(*)
5.5 9.5 11.0 11.0
ns
5.0
(**)
4.0 6.5 7.5 7.5
t
W
CK pulse Width,
(Count) HIGH or
LOW
3.3
(*)
2.0 4.5 7.5 7.5
ns
5.0
(**)
2.0 4.0 4.5 4.5
t
W
CK pulse Width,
(Load) HIGH or
LOW
3.3
(*)
2.0 3.0 3.5 3.5
ns
5.0
(**)
2.0 2.5 3.0 3.0
t
s
Setup Time HIGH
or LOW (INPUT to
CLOCK)
3.3
(*)
2.0 4.0 5.0 5.0
ns
5.0
(**)
1.5 3.0 4.0 4.0
t
n
Hold Time HIGH or
LOW (INPUT to
CLOCK)
3.3
(*)
-1.5 -0.5 0 0
ns
5.0
(**)
-1.0 0.5 1.0 1.0
t
s
Setup Time HIGH
or LOW (CLEAR
to
CLOCK)
3.3
(*)
1.0 3.0 4.0 4.0
ns
5.0
(**)
1.0 3.5 4.5 4.5
t
h
Hold Time HIGH or
LOW (CLEAR
to
CLOCK)
3.3
(*)
-0.5 0.5 1.0 1.0
ns
5.0
(**)
-0.3 0.5 1.0 1.0
t
s
Setup Time HIGH
or LOW ( LOAD
to
CLOCK)
3.3
(*)
3.0 5.0 8.0 8.0
ns
5.0
(**)
2.5 6.0 7.0 7.0
t
h
Hold Time HIGH or
LOW (LOAD
to
CLOCK)
3.3
(*)
-2.5 -1.0 -0.5 -0.5
ns
5.0
(**)
-1.5 0 0.5 0.5
t
s
Setup Time HIGH
or LOW (PE or TE
to CLOCK)
3.3
(*)
3.0 6.0 7.0 7.0
ns
5.0
(**)
2.0 4.0 5.0 5.0
t
h
Hold Time HIGH or
LOW (PE or TE to
CLOCK)
3.3
(*)
-2.0 -0.5 0 0
ns
5.0
(**)
-1.5 0 0.5 0.5
f
MAX
Maximum Clock
Frequency
3.3
(*)
70 200 60 60
MHz
5.0
(**)
110 200 95 95

74AC163TTR

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Counter Shift Registers Sync 4-Bit Counter
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS