6502

Maintenance
The 6500 half mask must be inspected before each use to ensure
it is in proper operating condition. Any damaged or defective
part must be replaced before use. The following procedure is
suggested.
1. Check the face mask for cracks, tears and dirt. Examine the
inhalation valves for signs of distortion, cracking or tearing.
2. Check that the head straps are intact and have good
elasticity.
3. Examine all plastic parts and gaskets for signs of cracking or
fatigue and replace if necessary.
4. Remove the exhalation valve cover and exhalation valve and
examine for signs of dirt, distortion, cracking, or tearing.
Replace the parts where necessary. Secure the valve cover
prior to use
Use Limitation
1. These respirators do not supply oxygen. Do not use in
oxygen deficient areas.*
2. Do not use for respiratory protection against atmospheric
contaminants which have poor warning properties, are
unknown or immediately dangerous to life and health, or
against chemicals, which generate high heats of reaction
with chemical filters.
3. Do not modify or alter this device.
4. The assembled respirator may not provide a satisfactory face
seal with certain physical characteristics (such as beards or
large side burns) resulting in leakage between the respirator
and the face. The user assumes all risks of bodily injury,
which may possibly result.
5. Do not use with unknown concentrations of contaminants.
6. Do not use for escape purposes.
7. Leave the work area immediately and check the integrity of
the respirator and replace respirator and / or filters if:
- Damage has occurred or is apparent.
- Breathing becomes dicult or increased breathing
resistance occurs.
- Dizziness or other distress occurs.
- You taste or smell the contaminant or an irritation occurs.
8. Store this device in a sealed container away from
contaminated areas when not in use.
5. Use strictly in accordance with respirator and filter user
instruction leaflet.
* 3M definition minimum 19.5% by volume oxygen
Materials
Component Material
Face seal Silicone Rubber
Overmould Nylon
Inhalation valve Polyisoprene
Exhalation Valve Nylon/Silicon
Straps Polyester fibre/Polyurethane elastic
Head cradle Polyethylene
Buckles Polypropylene
Fitting Instructions
1. Adjust head cradle size as needed to fit comfortably on head.
2. Place the respirator over the nose and mouth, fitting it
comfortably on the bridge of the nose, then pull the head
harness over the crown of the head. (1)
3. Take a bottom strap in each hand, place the straps at the
back of the neck and hook the straps together. (2)
4. Tighten the top head harness first by pulling on the ends of
the straps to achieve a comfortable and secure fit. Tighten
the bottom straps in a similar manner. (Strap tension may be
decreased by pushing out on the back side of the buckles).
(3)
IMPORTANT NOTICE: After initial donning of the 6500QL Quick
Latch Half Mask, once straps are adjusted to proper length,
subsequent donning can be done with quick latch initially in
open or closed position. To don with the quick latch in the open
position, follow steps as above for fitting the head harness, then
raise mask to the in-use position according to the procedure
described in the “Using Quick Latch Drop Down Suspension
section of these User Instructions.
Always follow instructions in User Instructions.
Quick Latch Operation
TO OPEN QUICK LATCH: Grasp the latch at chin level and pull up.
TO CLOSE QUICK LATCH: Grasp the facepiece with your thumb
on the bottom of the facepiece and your first two fingers on top
of the latch. Place the facepiece over your nose and mouth while
pushing down on the latch.
Fit Check
Perform a positive and/or negative pressure fit check each time
the respirator is donned.
Positive pressure face fit check (all Filters except 3M™ 6035,
6038 / 2000 Series Filters).
1. Place the palm of the hand over the exhalation valve cover
and exhale gently.
2. If the respirator bulges slightly and no air leakage between
the face and the respirator is detected, a proper fit has been
achieved.
3. If air leakage is detected, reposition the respirator on the
face and/or readjust the tension of the strap to eliminate the
leakage.
4. Repeat the above face fit check.
Negative pressure face fit check (3M™ 6035, 6038 / 2000
Series Filters)
1. Push the filter cover down (6035, 6038) or press your
thumbs into the central indentation of the filters (2000
series), inhale gently and hold your breath for five or ten
seconds.
2. If the respirator collapses slightly, a proper fit has been
achieved.
3. If air leakage is detected, reposition the respirator on the
face and/or readjust the tension of the straps to eliminate the
leakage.
4. Repeat the above face fit check.
5. If you cannot achieve a proper fit, do not enter the
contaminated area. See your supervisor.
EU_Master_01
3M is a trademark of 3M company.
Please recycle. © 3M 2014.
All rights reserved.
17935
Company name
Address line 1
Address line 2
Region / City
Country
Tel Number
Web URL
3M Personal Safety Division
EMEA Region
3M Centre,
Cain Road, Bracknell
Berkshire RG12 8HT
United Kingdom
Tel: +44 (0) 1344 858000
www.3M.eu/safety
Spare Parts
Part Description
6581 Head Harness Assembly
6582QL Quick Latch Head Harness Assembly
6583 Exhalation Valve
6593 Inhalation Valve
501 Retainer for 5000 Series Filters
603 Particulate Filter Platform
105 Face Seal Cleaner
106 Half Mask Carry Case
Respiratory Protection is only eective if it is correctly
selected, fitted and worn throughout the time when the wearer
is exposed to respiratory contaminants.
3M oers advice on the selection of products, and training in the
correct fitting and usage.
For more information on 3M products and services please call the
3M Health & Safety Helpline.
Important Notice
3M does not accept liability of any kind, be it direct or
consequential (including, but not limited to, loss of profits,
business and/or goodwill) arising from reliance upon any
information herein provided by 3M. The user is responsible for
determining the suitability of the products for their intended
use. Nothing in this statement will be deemed to exclude or
restrict 3M’s liability for death or personal injury arising from its
negligence.

6502

Mfr. #:
Manufacturer:
3M
Description:
RESPIRATOR, HALF FACEPIECE, MEDIUM, Safety Category:EN140, Protection Class:-, Respirator Type:Half, Product Range:6502 Series RoHS Compliant: NA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet