Maintenance
The 6500 half mask must be inspected before each use to ensure
it is in proper operating condition. Any damaged or defective
part must be replaced before use. The following procedure is
suggested.
1. Check the face mask for cracks, tears and dirt. Examine the
inhalation valves for signs of distortion, cracking or tearing.
2. Check that the head straps are intact and have good
elasticity.
3. Examine all plastic parts and gaskets for signs of cracking or
fatigue and replace if necessary.
4. Remove the exhalation valve cover and exhalation valve and
examine for signs of dirt, distortion, cracking, or tearing.
Replace the parts where necessary. Secure the valve cover
prior to use
Use Limitation
1. These respirators do not supply oxygen. Do not use in
oxygen deficient areas.*
2. Do not use for respiratory protection against atmospheric
contaminants which have poor warning properties, are
unknown or immediately dangerous to life and health, or
against chemicals, which generate high heats of reaction
with chemical filters.
3. Do not modify or alter this device.
4. The assembled respirator may not provide a satisfactory face
seal with certain physical characteristics (such as beards or
large side burns) resulting in leakage between the respirator
and the face. The user assumes all risks of bodily injury,
which may possibly result.
5. Do not use with unknown concentrations of contaminants.
6. Do not use for escape purposes.
7. Leave the work area immediately and check the integrity of
the respirator and replace respirator and / or filters if:
- Damage has occurred or is apparent.
- Breathing becomes dicult or increased breathing
resistance occurs.
- Dizziness or other distress occurs.
- You taste or smell the contaminant or an irritation occurs.
8. Store this device in a sealed container away from
contaminated areas when not in use.
5. Use strictly in accordance with respirator and filter user
instruction leaflet.
* 3M definition minimum 19.5% by volume oxygen
Materials
Component Material
Face seal Silicone Rubber
Overmould Nylon
Inhalation valve Polyisoprene
Exhalation Valve Nylon/Silicon
Straps Polyester fibre/Polyurethane elastic
Head cradle Polyethylene
Buckles Polypropylene
Fitting Instructions
1. Adjust head cradle size as needed to fit comfortably on head.
2. Place the respirator over the nose and mouth, fitting it
comfortably on the bridge of the nose, then pull the head
harness over the crown of the head. (1)
3. Take a bottom strap in each hand, place the straps at the
back of the neck and hook the straps together. (2)
4. Tighten the top head harness first by pulling on the ends of
the straps to achieve a comfortable and secure fit. Tighten
the bottom straps in a similar manner. (Strap tension may be
decreased by pushing out on the back side of the buckles).
(3)
IMPORTANT NOTICE: After initial donning of the 6500QL Quick
Latch Half Mask, once straps are adjusted to proper length,
subsequent donning can be done with quick latch initially in
open or closed position. To don with the quick latch in the open
position, follow steps as above for fitting the head harness, then
raise mask to the in-use position according to the procedure
described in the “Using Quick Latch Drop Down Suspension”
section of these User Instructions.
Always follow instructions in User Instructions.