DRC-60A

Suggested Application
1.Backup connection for AC interruption
(1) Please refer to Fig1.1 for suggested connection.
The power supply charges the battery and provides energy to the load at the same time whenAC mains is OK.
The battery starts to supply power to the load when AC mains fails.
60W Single Output with Battery Charger (UPS Function)
DRC-60 series
2.Alarm signal for AC OK and battery low
(1) Alarm Signal is sent out through " AC OK " & " Battery Low " pins via relay contact.
(2) An external voltage source is required for this function. The maximum applied voltage is 30V and the maximum sink current is 1A. Please refer to Fig 2.2.
(3) Table2.1 explains the alarm function built in the power supply
V-V+Bat-Bat+
Load
A : 12V
B : 24V
Battery
++
--
Fig 1.1 Suggested system connection
External voltage sorece (V) and resistor (R)
(The max. Sink is 1A and 30V)
AC OK (Battery low)
Fig 2.2 Internal circuit of AC OK (Battery Low), via relay contact
Function
Output of alarm
Low or short
Low or short
High or open (External applied voltage 30V max.)
High or open (External applied voltage 30V max.)
Description
The signal is "Low" when the power supply turns ON.
The signal is "Low" when the voltage of battery is under A:11V, B:22V.
The signal is "High" when the voltage of battery is above A:11V, B:22V.
The signal turns to be "High" when the power supply turns OFF.
AC OK
Battery Low
Table 2.1 Explanation of alarm signal
(4) AC OK signal (RL1,referring to Block Diagram) will go into hiccup mode when the overload protecton is activated.
R
V
+
DC OK
+V ADJ
File Name:DRC-60-SPEC 2018-01-12
60W Single Output with Battery Charger (UPS Function)
DRC-60 series
Terminal Pin No. Assignment (TB2):
Terminal Pin No. Assignment (TB1):
Pin No.
Pin No.
Pin No.
1
1
5,6
7,8
4
2
3
2
3
Assignment
Assignment
Assignment
-V
AC/L or DC+
+V
Bat. +
AC/N or DC-
FG
AC OK
Bat. Low
Bat. -
Mechanical SpecificationMechanical Specification
Installation Instruction
Mechanical SpecificationMechanical Specification
Case No.962A Unit:mm
+
12345678
40
23
TB1
TB2
1
DC OK
+V ADJ
3.81 7×
7.57.5
90
100
Back View
35
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the Instruction manual.
ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:DRC-60-SPEC 2018-01-12

DRC-60A