RSD-100D-12

SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE
RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020
5 ~ 95% RH non-condensing
-40 ~ +85 , 5 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
254.1K hrs min. MIL-HDBK-217F (25 )
161*68*36mm (L*W*H)
0.6Kg; 24pcs/15.4Kg/0.98CUFT
File Name:RSD-100-SPEC 2018-01-15
100W Railway Single Output DC-DC Converter
Features :
RSD-100 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 5)
ENVIRONMENT
PROTECTION
1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Strongly recommended that external output capacitance should not exceed 5000uF. :(Only for RSD-100-5 / -12)
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
RSD-100B-5
RSD-100B-12 RSD-100C-12 RSD-100D-12
RSD-100B-24 RSD-100C-24
RSD-100D-24
RSD-100C-5 RSD-100D-5
5V 12V 24V 5V 12V 24V 5V 12V 24V
20A 8.4A 4.2A 20A 8.4A 4.2A 20A 8.4A 4.2A
0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A
100W 100.8W 100.8W 100W 100.8W 100.8W 100W 100.8W 100.8W
100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p
±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
±0.5% ±0.3% ±0.2% ±0.5% ±0.3% ±0.2% ±0.5% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
800ms, 50ms at full load
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
88%
4.8A/24V
89% 89% 89%
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
67.2 ~ 143VDC
57.6 ~ 154VDC
91% 91% 89.5% 91% 90%
4.8A/24V 4.8A/24V 2.4A/48V
30A/48VDC
2.4A/48V 2.4A/48V 1.2A/110V
30A/110VDC
1.2A/110V 1.2A/110V
30A/24VDC
IEC60950-1(LVD) EAC TP TC 004
, approved
Compliance to EN50155 and EN45545-2 railway standard
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Input reverse polarity
4000VDC I/O isolation
Cooling by free air convection
Half encapsulated
Built-in constant current limiting circuit
1U low profile 36mm
All using 105 long life electrolytic capacitors
LED indicator for power on
100% full load burn-in test
3 years warranty
5.75 ~ 7V 5.75 ~ 7V 5.75 ~ 7V13.8 ~ 16.2V 13.8 ~ 16.2V 13.8 ~ 16.2V27.6 ~ 32.4V 27.6 ~ 32.4V 27.6 ~ 32.4V
EMC IMMUNITY
EMC EMISSION
HOLD UP TIME (Typ.)
CONTINUOUS
1 SEC.
B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
RAILWAY STANDARD
EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC ; EN45545-2 for fire protection
-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance℃℃
Protection type : Shut down o/p voltage, re-power on to recover
Mechanical Specification
Case No.999A Unit:mm
fosc : 130KHz
Block Diagram
CIRCUIT
DETECTION
O.L.P.
O.V.P.
EMI
FILTER
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
PWM
FG
Input Fuse
There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown
as below.
Type
B
C
D
Fuse Type
Time-Lag
Time-Lag
Time-Lag
Reference and Rating
Conquer UDA-A, 10A, 250V
Conquer UDA-A, 5A, 250V
Conquer UDA-A, 3.15A, 250V
I/P
O/P
1
2
4-R1.75
2.5
LED
6.5
55
68
2.5
2-R1.75
156
12max.
12max.
1
2
3
161
9.5
25
36
8.2
156
100W Railway Single Output DC-DC Converter
RSD-100 series
Input Terminal Pin No. Assignment :
Output Terminal Pin No. Assignment :
Pin No. Pin No.
1
1
2
2
3
Assignment Assignment
DC INPUT V+
DC OUTPUT -V
DC INPUT V-
DC OUTPUT +V
File Name:RSD-100-SPEC 2018-01-15
57.3
53.7
0
5
10
15
20
25
30
50 55 60 65 70
Turn O n
Turn O ff
27.625.6
30
0
5
10
15
20
25
30
25 27 29 31 33 35
Tur n O n
Tur n O ff
13.8
12.8
0
5
10
15
20
25
30
12 13 14 15 16 17
Tur n O n
Tur n O ff
Input Reverse Polarity Protection
Input Range and Transient Ability
Input Under-Voltage Protection
Inrush Current
There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect
the unit.
The series has a wide range input capability. Within 30% of rated input voltage, it can be executed at full-load operation and operate properly; with 40% of rated input± ±
voltage, it can withstand that for 1 second.
If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin,
please refer to the cruve below.
Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing
the start-up.
TIME
TIME
TIME
TIME
TIME
TIME
LOAD
LOAD
LOAD
LOAD
LOAD
LOAD
Vin Vin Vin
Vo Vo Vo
Hold-up Time
Output Voltage Adjustment
D type is in compliance with S2 level, while B and C types are in compliance with S1 level at full load output condition. To fulfil the requirements of S2 level, B and C
This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.
types require de-rating their output load to 70%, please refer to the curve diagrams below.
RSD-100B-5
RSD-100B-24
RSD-100C-5
RSD-100B-12
RSD-100C-24
RSD-100C-12
RSD-100B-24
RSD-100D-24
RSD-100C-24
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0ms 10ms 20ms 30ms 40ms 50ms 60ms 70ms 80ms 90ms 100ms 0ms 0ms10ms 10ms20ms 20ms30ms 30ms40ms 40ms50ms 50ms60ms 60ms70ms 70ms80ms 80ms90ms 90ms
100W Railway Single Output DC-DC Converter
RSD-100 series
File Name:RSD-100-SPEC 2018-01-15

RSD-100D-12

Mfr. #:
Manufacturer:
Description:
Isolated DC/DC Converters 100.8W 12V 8.4A 57.6-154VDC in
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union