ACPL-072L-000E

4
ACPL-072L Small Outline SO-8 Package
XXXV
YWW
8 7 6 5
4321
5.994 ± 0.203
(0.236 ± 0.008)
3.937 ± 0.127
(0.155 ± 0.005)
0.406 ± 0.076
(0.016 ± 0.003)
1.270
(0.050)
BSC
5.080 ± 0.127
(0.200 ± 0.005)
3.175 ± 0.127
(0.125 ± 0.005)
1.524
(0.060)
45 ° X
0.432
(0.017)
0.228 ± 0.025
(0.009 ± 0.001)
TYPE NUMBER
(LAST 3 DIGITS)
DATE CODE
0.305
(0.012)
MIN.
TOTAL PACKAGE LENGTH (INCLUSIVE OF MOLD FLASH)
5.207 ± 0.254 (0.205 ± 0.010)
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES) MAX.
OPTION NUMBER 500 NOT MARKED.
NOTE: FLOATING LEAD PROTRUSION IS 0.15 mm (6 mils) MAX.
0.203 ± 0.102
(0.008 ± 0.004)
7 °
PIN ONE
0 ~ 7 °
*
*
7.49 (0.295)
1.9 (0.075)
0.64 (0.025)
LAND PATTERN RECOMMENDATION
5
Regulatory Information
Both ACPL-072L and ACPL-772L are approved by the following organizations:
Solder Reflow Temperature Profile
Note: Non-halide flux should be used
Recommended Pb-Free IR Profile
Note: Non-halide flux should be used
217
˚
C
RAMP-DOWN
6
˚
C/SEC. MAX.
RAMP-UP
3
˚
C/SEC. MAX.
150 - 200
˚
C
260 +0/-5
˚
C
t 25
˚
C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5
˚
C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NO TES:
THE TIME FROM 25
˚
C to PEAK TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200
˚
C, T
smin
= 150
˚
C
0
TIME (SECONDS)
TEMPERATURE (
˚
C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160 ˚C
140 ˚C
150 ˚C
PEAK
TEMP.
245 ˚C
PEAK
TEMP.
240 ˚C
PEAK
TEMP.
230˚C
SOLDERING
TIME
200˚C
PREHEATING TIME
150 ˚C, 90 + 30 SEC.
2.5˚ C ± 0.5 ˚C/SEC.
3˚C + 1 ˚C/- 0.5 ˚C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3˚C + 1 ˚C/- 0.5 ˚C/SEC.
REFLOW HEATING RATE 2.5˚C ± 0.5 ˚C/SEC.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
(option 060 only)
UL
Approved under UL 1577, component recognition
program up, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5,
File CA 88324.
6
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description Symbol
ACPL-772L
Option 060
ACPL-072L
Option 060 Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage 150 Vrms
for rated mains voltage 300 Vrms
for rated mains voltage 450 Vrms
I – IV
I – IV
I – III
I – IV
I – III
Climatic Classification 55/105/21 55/105/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 560 V
peak
Input to Output Test Voltage, Method b**
V
IORM
x 1.875=V
PR
, 100% Production Test with t
m
=1 sec,
Partial discharge < 5 pC
V
PR
1181 1050 V
peak
Input to Output Test Voltage, Method a**
V
IORM
x 1.5=V
PR
, Type and Sample Test, t
m
=60 sec, Partial discharge < 5 pC
V
PR
945 840 V
peak
Highest Allowable Overvoltage (Transient Overvoltage t
ini
= 10 sec) V
IOTM
6000 4000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure,
also see Figure 2.
Case Temperature
Input Current
Output Power
T
S
I
S, INPUT
P
S, OUTPUT
175
230
600
150
150
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
IO
>109 >109
W
* Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Surface mount classification is class A in accordance with CECCOO802.
** Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
Note: These optocouplers are suitable for “safe electrical isolation only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
Note: The surface mount classification is Class A in accordance with CECC 00802.
Table 2. Insulation and Safety Related Specifications
Parameter Symbol
Value
Units Conditions
ACPL-
772L ACPL-072L
Minimum External
Air Gap (Clearance)
L(101) 7.1 4.9 mm Measured from input terminals to output termi-
nals, shortest distance through air.
Minimum External
Tracking (Creepage)
L(102) 7.4 4.8 mm Measured from input terminals to output termi-
nals, shortest distance path along body.
Minimum Internal Plastic
Gap (Internal Clearance)
0.08 0.08 mm Through insulation distance conductor to con-
ductor, usually the straight line distance thickness
between the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI >175 >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
All Avago Technologies data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as
a starting point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit board,
minimum creepage and clearance requirements must be met as specified for individual equipment standards. For creepage, the shortest distance
path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered.
There are recommended techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances.
Creepage and clearance distances will also change depending on factors such as pollution degree and insulation level.

ACPL-072L-000E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 3.3V/5V 25MBd
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: