M7100
Pressure Transducer
SENSOR SOLUTIONS ///M7100
4 = 7-16-20 UNF, SAE J1926-2, Male, w/ O-Ring
F = G1/4-19, BS5380, Female
P = 7/16-20UNF Female w/ Integral Valve Depressor;
1/4 Flare Gasket SAE J513C, Copper
Q = M10 x 1.0, ISO 6149-2, Male
S = M12 x 1.5, ISO 6149-2, Male
G = M14 x 1.5, ISO 6149-2, Male
U = G1/4, DIN 3852-E, Male
Notes: Installation
*T.F.F.T.: Turns From Finger Tight
Transducers can be installed by either spanner or deep socket. Torque values provided are for reference: actual torque depends upon mating
port material, surface finish, lubrication and sealing mechanism. Transducers calibration and/or zero may shift if part is over-torqued during
installation. Check for a zero shift after installing.
Packard Metri-Pack 150 Series
0.003 mm Sn over
0.0005 – 0.001 mm Cu
Terminals P/N: 8100-3067/8
AMP Econoseal-J Mark II 070 Series
0.0004 mm Au over
0.0013 mm Ni
Notes: Connector
Do not apply torque to the connector housing of transducer.
To ensure proper environmental sealing and electrical connection when using a mating connector, follow the manufacturer’s installation
guidelines.