TXS2SA-9V-X

–1–
ASCTB15E 201407-T
ORDERING INFORMATION
High sensitivity, 50 mW
Nominal operating power,
2 Form C and 1 A relays
TX-S RELAYS
RoHS compliant
FEATURES
1. High sensitivity and Nominal
operating power of 50mW
2. Compact size
15.0 (L) × 7.4 (W) × 8.2 (H) mm
.591 (L) × .291 (W) × .323 (H) inch
3. High contact reliability
High contact reliability is achieved by
the use of gold-clad twin crossbar
contacts, low-gas formation materials,
mold sealing the coil section, and by
controlling organic gas in the coil.
*We also offer a range of products
with AgPd contacts suitable for use
in low level load analog circuits
(Max. 10V DC 10 mA).
4. Outstanding surge resistance.
1,500 V 10×160 μsec. (FCC part 68)
(open contacts)
2,500 V 2×10 μsec. (Telcordia)
(contact and coil)
5. Low thermal electromotive force
(approx. 0.3 μV)
TYPICAL APPLICATIONS
1. Communications
(XDSL, Transmission)
2. Measurement
3. Security
4. Home appliances, and audio/visual
equipment
5. Medical equipment
Nominal coil voltage (DC)
3, 4.5, 6, 9, 12, 24V
Contact arrangement
2: 2 Form C
TXS 2
Terminal shape
Nil: Standard PC board terminal or surface-mount terminal
Contact material
Nil:
1:
Standard contact (Ag+Au clad)
AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable)
Operating function
Nil:
LT:
Single side stable
2 coil latching
Surface-mount availability
Nil:
SA:
Standard PC board terminal type
SA type
Packing style
Nil:
X:
Z:
Tube packing
Tape and reel (picked from 1/3/4/5-pin side)
Tape and reel packing (picked from the 8/9/10/12-pin side)
TX-S
–2–
ASCTB15E 201407-T
TYPES
1. Standard PC board terminal
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2. Surface-mount terminal
1) Tube packing
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Tape and reel packing
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please add “-1” to the end of the part number for AgPd contacts (low level load). (Ex. TXS2SA-3V-1-Z)
RATING
1. Coil data
1) Single side stable
2) 2 coil latching
*Pulse drive (JIS C 5442-1986)
Contact
arrangement
Nominal coil
voltage
Single side stable 2 coil latching
Part No. Part No.
2 Form C
3 V DC TXS2-3V TXS2-LT-3V
4.5 V DC TXS2-4.5V TXS2-LT-4.5V
6 V DC TXS2-6V TXS2-LT-6V
9 V DC TXS2-9V TXS2-LT-9V
12 V DC TXS2-12V TXS2-LT-12V
24 V DC TXS2-24V TXS2-LT-24V
Contact
arrangement
Nominal coil
voltage
Single side stable 2 coil latching
Part No. Part No.
2 Form C
3 V DC TXS2SA-3V TXS2SA-LT-3V
4.5 V DC TXS2SA-4.5V TXS2SA-LT-4.5V
6 V DC TXS2SA-6V TXS2SA-LT-6V
9 V DC TXS2SA-9V TXS2SA-LT-9V
12 V DC TXS2SA-12V TXS2SA-LT-12V
24 V DC TXS2SA-24V TXS2SA-LT-24V
Contact
arrangement
Nominal coil
voltage
Single side stable 2 coil latching
Part No. Part No.
2 Form C
3 V DC TXS2SA-3V-Z TXS2SA-LT-3V-Z
4.5 V DC TXS2SA-4.5V-Z TXS2SA-LT-4.5V-Z
6 V DC TXS2SA-6V-Z TXS2SA-LT-6V-Z
9 V DC TXS2SA-9V-Z TXS2SA-LT-9V-Z
12 V DC TXS2SA-12V-Z TXS2SA-LT-12V-Z
24 V DC TXS2SA-24V-Z TXS2SA-LT-24V-Z
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
3 V DC
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
16.7 mA 180 Ω
50 mW
150%V of
nominal voltage
4.5 V DC 11.1 mA 405 Ω
6 V DC 8.3 mA 720 Ω
9 V DC 5.6 mA 1,620 Ω
12 V DC 4.2 mA 2,880 Ω
24 V DC 2.9 mA 8,229 Ω 70 mW
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3 V DC
80%V or less of
nominal voltage*
(Initial)
80%V or less of
nominal voltage*
(Initial)
23.3 mA 23.3 mA 129 Ω 129 Ω
70 mW 70 mW
150%V of
nominal voltage
4.5 V DC 15.6 mA 15.6 mA 289 Ω 289 Ω
6 V DC 11.7 mA 11.7 mA 514 Ω 514 Ω
9 V DC 7.8 mA 7.8 mA 1,157 Ω 1,157 Ω
12 V DC 5.8 mA 5.8 mA 2,057 Ω 2,057 Ω
24 V DC 6.3 mA 6.3 mA 3,840 Ω 3,840 Ω 150 mW 150 mW
TX-S
–3–
ASCTB15E 201407-T
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. AgPd contact type is available for low level load switching (10V DC, 10mA max. level).
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 2 Form C
Initial contact resistance, max. Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Rating
Nominal switching capacity 1 A 30 V DC (resistive load)
Max. switching power 30 W (DC) (resistive load)
Max. switching voltage 110V DC
Max. switching current 1 A
Min. switching capacity (Reference value)*
1
10μA 10mV DC
Nominal operating
power
Single side stable 50 mW (3 to 12 V DC), 70 mW (24 V DC)
2 coil latching 70 mW (3 to 12 V DC), 150 mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 1,800 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160μs) (FCC Part 68)
Between contacts and coil 2,500 V (2×10μs) (Telcordia)
Temperature rise (at 20°C 68°F)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Operate time [Set time] (at 20°C 68°F) Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)
Max. 5 ms [Max. 5 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Destructive Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical Min. 5×10
7
(at 180 cpm)
Electrical (Standard contact) Min. 2×10
5
(1 A 30 V DC resistive) (at 20 cpm)
Conditions
Conditions for operation, transport and storage*
2
Ambient temperature: –40°C to +70°C –40°F to +158°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 2 g .071 oz
1. Maximum switching capacity 2. Life curve 3. Mechanical life
Tested sample: TXS2-4.5V, 10 pcs.
Operating speed: 180 cpm
30
100
200
1.0
0.5
0.4
0.3
0.2
Contact current, A
DC resistive load
(cos = 1)
φ
Contact voltage, V
0 0.5 1.0
100
10
Switching current, A
No. of operations ×10
4
30V DC
resistive load
0
10
100 5,0001,00010
20
30
40
50
60
70
80
90
100
Min.
No. of operations, ×10
4
Ratio against the rated voltage, %V
Pick-up voltage
Drop-out voltage
Max.
Min.
Max.

TXS2SA-9V-X

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Low Signal Relays - PCB 1A 9VDC 50MW SMD RELAY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union