YR0K505111S000BE

Application Headers
Quick Start
Renesas Starter Kit
for RX111
Application Headers
Digilent
Pmod
compatible
(For Display)
Digilent
Pmod
Compatible
DC Power Jack
Power LED
Reset
Switch
User LEDs
E1 Header
User Switches
Analog Adjust
E1
Debugger
USB Host
LIN
Header
USB
Function
USB to
Serial
Pmod
TM
compatible
display
NOTE: This Quick Start Guide covers installation of the e
2
studio DVD.
1. Installation
Do not connect the E1 debugger module until the software support has been installed.
1. Insert the DVD into your computer’s DVD-ROM drive. The DVD should automatically run the installation program. If
the installer does not start, browse to the DVD root folder and double click on ‘setup.exe’.
2. Windows 7 / Vista users may see “User Account Control” dialog box. If applicable, enter the administrator
password and click ‘Yes’.
3. The installer welcome screen will open. Follow the on-screen instructions to install the RSK software. This process
will take several minutes.
Note:
When prompted to specify a different location for installing any of the tools, it is recommended that default entries are
accepted.
The Windows driver signing or Windows Security dialog boxes may be displayed. Please accept the driver to continue.
2. Connection
4. Fit the Pmod™ Display module to the connector markedPmod™ Display’ on the diagram. Ensure all the pins of the
connector are correctly inserted in the socket.
5. Connect the E1 debugger module to the connector marked ‘E1 Header on the diagram using the ribbon cable.
6. Connect the E1 debugger module to a spare USB port of your PC. The green ‘ACT’ LED on the E1 debugger will
flash.
7. Please follow the steps below to install the drivers. Note that administrator privileges are required to install the
drivers.
Windows™ XP
Windows™ 7 / Vista
a. Select option ‘No, not this time’ in the “Found New
Hardware” Wizard dialog, and click the Nextbutton.
A “Device driver software installed successfully” pop-
up will appear in the Windows toolbar and
installation will complete.
b. Verify the “Recommended” option is selected and
click ‘Next’.
c. Click Finishto close the wizard.
8. The green ‘ACT’ LED on the E1 debugger will illuminate.
3. Importing Sample Code into e
2
studio
e
2
studio integrates various tools such as compiler, assembler, debugger and editor into a common graphical user
interface. Start e
2
studio from the Start menu:
Start > All Programs > Renesas Electronics e2studio > Renesas e2studio
9. In the ‘Select a workspace’ folder that appears, browse a suitable location and folder name to save your new
workspace. A Windowsadministrator dialog box that may appear stating that administrator privileges are
required, click <Yes> to continue.
10. In the Toolchain registry dialog select Renesas Toolchains and ensure thatRXC v1.02.01’ is selected. Click
‘Register’. A dialog will appear "Selected Toolchains were successfully integrated with e2studio". Click OK.
11. In the e
2
studio welcome screen, click the ‘Go to the workbench’ arrow icon, on the far right.
12. Right-click in the project explorer window, and select ‘Import’.
13. Under ‘Import Source’ select General > Existing Projects into Workspace, and click ‘Next’.
14. Click the ‘Browse’ button, and locate the following root project directory:
‘C:\Renesas\Workspace\RSK\RSKRX111
15. Ensure the ‘Copy projects into workspace’ option is ticked and then click ‘Finish’.
4. Programming and Debug
16. Left-click the Tutorial project to select it, then click the arrow next to the build button (hammer icon),
and select ‘HardwareDebug’ from the drop down menu.
17. e
2
studio will now build the project. Once this is complete, debugging can be started by clicking the
arrow next to the debug button (bug icon), and selecting ‘Debug Configurations’.
18. Click the arrow next to the entry ‘Renesas GDB Hardware Debugging’ to
expand the list. Select the configuration entry ‘Tutorial’.
19. Click the ‘Debugger’ tab, then the ‘Connection Settings’ secondary tab. Review the settings listed in the screenshot
below.
20. Click the ‘Debug’ button to download the code to the
target, and begin debugging.
21. A firewall warning may be displayed for 'e2-server-
gdb.exe'. Check the 'Private networks, such as my home
or work network' box and click 'Allow access'.
22. A user account control dialog may be displayed. Enter
the administrator password and click <Yes>.
23. e
2
studio will ask you to change to the ‘Renesas Debug
Perspective’, click ‘Yes’.
24. Once the code has been downloaded, click the ‘Resume’ button to run the code up to the main
function. Click ‘Resume’ again to run the target through the rest of the code.
25. You will see the LEDs flash on the board. Pressing any of the switches on the RSK will allow you to
control the rate of flashing using the Analog Adjust control.
26. Click the 'Suspend' button. The program will stop and the source code will be opened at the current
program counter.

YR0K505111S000BE

Mfr. #:
Manufacturer:
Description:
R5F51115ADFM Microcontroller Starter Kit 0.032768MHz/20MHz CPU 2MB I2C EEPROM Win 7/Win XP OS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet