MODEL SNTUNS100F05 SNTUNS100F12 SNTUNS100F24
MAX OUTPUT WATTAGE[W] 100.0 100.8 100.8
DC OUTPUT 5V 20A 12V 8.4A 24V 4.2A
SPECIFICATIONS
MODEL SNTUNS100F05 SNTUNS100F12 SNTUNS100F24
INPUT
VOLTAGE[V]
AC85 - 264 1f (Please refer to the instruction manua 1.1 and 3.2)
CURRENT[A]
ACIN 100V
1.3typ (Io=100%)
ACIN 200V
0.7typ (Io=100%)
FREQUENCY[Hz] 50/60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
79typ 81typ 82typ
ACIN 200V
82typ 83typ 84typ
POWER FACTOR (Io=100%)
ACIN 100V
0.95typ
ACIN 200V
0.90typ
INRUSH CURRENT[A]
ACIN 100V
20yp (Io=100%) (At cold start) (Ta=25C)
ACIN 200V
40typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA]
0.4/0.75 (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 51224
CURRENT[A] 20 8.4 4.2
LINE REGULATION[mV] 10max 24max 48max
LOAD REGULATION[mV] 150max 100max 100max
RIPPLE[mVp-p]
0 to +95C
*1
80max 120max 120max
-20 to 0C
*1
140max 160max 160max
0 to 15% Load
*1
160max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +95C
*1
120max 150max 150max
-20 to 0C
*1
200max 200max 250max
0 to 15% Load
*1
240max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +65C
50max 120max 240max
-20 to +95C
100max 240max 480max
DRIFT[mV]
*
2
20max 40max 90max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 - 5.50 10.80 - 13.20 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
5.00 - 5.15 12.00 - 12.48 24.00 - 24.96
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.00 13.90 - 16.35 27.60 - 32.40
REMOTE SENSING Optional (Option:K)
--
REMOTE ON/OFF Not provided
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +95C (On aluminum base plate), 20 - 95%RH (Non condensing)
*
4
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +95C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 (Class A)
*
3
OTHERS CASE SIZE/WEIGHT
74X37X150mm [2.91X1.46X5.91 inches] (WXHXD) / 340g max
*1 Refer to Instruction manual for measuring method of an electrical property.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Please contact us about another class.
*4 Refer to Instruction manual 3.2 and 3.3.
SNTU
me_sntu.indd SNTU-4me sntu indd SNTU-4 2015/06/19 16:12:592015/06/19 16:12:59