60W Single Output Encapsulated Type
IRM-60 series
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME
(Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY
(Typ.)
INPUT
INRUSH CURRENT
(Typ.)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING HUMIDITY
WORKING TEMP.
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT
(Typ.)
1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
50ms/230VAC 12ms/115VAC at full load
85 ~ 264VAC
47 ~ 440Hz
87.5%84% 89%
12.6 ~ 16.2V
90%
15.75 ~ 20.25V
91%
25.2 ~ 32.4V 50.4 ~ 64.8V
1.8A/115VAC 1A/230VAC
COLD START 30A/115VAC 60A/230VAC
115%~160% rated output power
5.25 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to "Derating Curve")℃
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
1226Khrs min. MIL-HDBK-217F (25 )℃
PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)
PCB mounting style : 0.195Kg;60pcs/12.7Kg/0.97CUFT Screw terminal style :0.228Kg;50pcs/12.4Kg/0.55CUFT
±1.0%
±0.5%
±1.0%
±0.5%
±0.5%
±0.5% ±0.5%
±0.5% ±0.5%
±0.5%
±2.5% ±2.5% ±2.5% ±2.5% ±2.5%
80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p
12V 15V 24V 48V
10A 5A 4A 2.5A 1.25A
0 ~ 10A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A
50W 60W 60W 60W 60W
IRM-60-5 IRM-60-12 IRM-60-15 IRM-60-24 IRM-60-48
SAFETY STANDARDS
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher ℃℃
than 2000m(6500ft).
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Protection type : Shut off o/p voltage, clamping by zener diode
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level (surge L-N : 1KV), criteria A, EAC TP TC 020
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
UL60950-1, TUV EN60950-1, approvedEAC TP TC 004
5V
EMC IMMUNITY
EMC EMISSION
LEAKAGE CURRENT
< 0.25mA/240VAC
File Name:IRM-60-SPEC 2018-01-12