date 03/08/2017 │ page 2 of 4CUI Inc │ SERIES: SWI15-E │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current 0.5 A
inrush current at 240 Vac, 25°C, cold start 50 A
leakage current 0.25 mA
no load power consumption 0.075 W
OUTPUT
parameter conditions/description min typ max units
voltage set point accuracy at 60% load ±2 %
line regulation measured from 100~240 Vac, full load ±1 %
load regulation
measured from 60~100% load and 60~20% load
5 Vdc output model
all other models
±4
±2
%
%
hold-up time at 115 Vac 10 ms
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection
hiccup mode, auto recovery
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
7.14
12.1
15.8
19.5
28.4
Vdc
Vdc
Vdc
Vdc
Vdc
over current protection hiccup mode, auto recovery 120 140 %
short circuit protection continuous, hiccup mode, auto recovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output for 1 minute
3,000
4,242
Vac
Vdc
isolation resistance input to output 100 MΩ
safety approvals GS EN 60950-1, IEC 60950-1
safety class Class II
EMI/EMC CE, EN 55022 Class B
MTBF as per MIL-HDBK-217F at 115 Vac, full load, 25°C 330,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature -20 40 °C
storage temperature -20 85 °C
For more information, please visit the product page | For information on related products, view Dc Power Jacks