Mechanical Specification
Case No.250 Unit:mm
※ Mounting Instruction
Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque
1
2
M3 6mm
M4 7mm
1600W Power Supply with Single Output
RSP-1600 series
4
Remote
ON-OFF
2
7,8,9
GND-AUX
NC
A0,A1,A2
Auxiliary voltage output GND.
The signal return is isolated from the output terminals (+V & -V).
For standard model: Retain for future use.
For PMBus / CANBus model: PMBus / CANBus interface address lines. (Note.1)
Pin No.
5
6
3
1
Function
DC-OK
T-ALARM
+5V-AUX
+12V-AUX
Description
High (4.5 ~ 5.5V) : When the Vout 80% 5%.≦±
Low (-0.1 ~ 0.5V) : When Vout 80% 5%.≧±
The maximum sourcing current is 10mA and only for output. (Note.2)
Auxiliary voltage output, 4.5~5.5V, referenced to GND-AUX (pin2).
Auxiliary voltage output, 10.6~13.2V, referenced to GND-AUX (pin2).
The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by “Remote ON-OFF
The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by “Remote ON-OFF”.
12
11
10
PV
PC
NC
Connection for output voltage . (Note.1)programming
15 +S
Positive sensing for remote sense.
High (4.5 ~ 5.5V) : When the internal temperature exceeds the limit of temperature alarm, or when Fan fails.
Low (-0.1 ~ 0.5V) : When the internal temperature is normal, and when Fan normally works.
The maximum sourcing current is 10mA and only for output(Note.2)
Connection for constant current level programming. (Note.1)
Retain for future use.
1
2
15
16
※ Control Pin No. Assignment( ) : HRS DF11-16DP-2DS or equivalentCN1
Mating Housing
Terminal
HRS DF11-16DS or equivalent
HRS DF11-**SC or equivalent
6~8Kgf-cm
7~1 Kgf-cm0
16 -S
Negative sensing for remote sense.
15
16
LED
SW1
2
8
-V
+V
2
1
10
2
3
9
I/P
CN1 CN500
28
38
1
2
12 max.
ψ6.5
13
(Bottom View)
3-M3 L=4
16.1
70
7.5
264.7
5.8
252
(Top View)
22.8
22.8
42.5
41
300
5.8
252
1
1
1
2 2
1 1
2-M4 L=5
2-M4 L=5
1
7
Air flow
85
direction
30
21.6
29.6
20
SVR
13
14
+V (Signal)
-V (Signal)
Positive output voltage signal.
Negative output voltage signal.
It is for local sense; it cannot be connected directly to the load.
It is for local sense and certain function reference; it cannot be connected directly to the load.
The unit can turn the output ON/OFF by electrical signal or dry contact between and . (Note.2)Remote ON/OFF +5V-AUX
Short (4.5 ~ 5.5V) : Power ON ; Open (0 ~ 0.5V) : Power OFF ; The maximum input voltage is 5.5V.
Mounting Screw
Mounting Surface
Chassis of RSP-1600
2-M3
File Name:RSP-1600-SPEC 2018-01-15
Note.1: Non-isolated signal, referenced to [-V(signal)].
Note.2: Isolated signal, referenced to GND-AUX.