Spartan/XL Family One-Time Programmable Configuration PROMs (XC17S00/XL)
DS030 (v1.12) June 20, 2008 www.xilinx.com
Product Specification 7
R
XC17S05XL, XC17S10XL, XC17S20XL, XC17S30XL, XC17S40XL, XC17S50XL,
XC17S100XL, XC17S150XL
Absolute Maximum Ratings
(1)
Operating Conditions
(1)
DC Characteristics Over Operating Condition
Symbol Description Value Units
V
CC
Supply voltage relative to GND –0.5 to +4.0 V
V
IN
Input voltage with respect to GND –0.5 to V
CC
+0.5 V
V
TS
Voltage applied to High-Z output –0.5 to V
CC
+0.5 V
T
STG
Storage temperature (ambient) –65 to +150 °C
Notes:
1. Stresses beyond those listed under Absolute Maximum Ratings can cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those listed under Operating Conditions is not implied.
Exposure to Absolute Maximum Ratings conditions for extended periods of time can affect device reliability.
Symbol Description Min Max Units
V
CC
Commercial Supply voltage relative to GND (T
A
= 0°C to +70°C) 3.0 3.6 V
Industrial Supply voltage relative to GND (T
A
= –40°C to +85°C) 3.0 3.6 V
Notes:
1. During normal read operation both V
CC
pins must be connected together.
Symbol Description Min Max Units
V
IH
High-level input voltage 2.0 V
CC
V
V
IL
Low-level input voltage 0 0.8 V
V
OH
High-level output voltage (I
OH
= –3 mA) 2.4 – V
V
OL
Low-level output voltage (I
OL
= +3 mA) – 0.4 V
I
CCA
Supply current, active mode (at maximum frequency) – 5 mA
I
CCS
Supply current, standby mode – 50
(1)
μA
I
L
Input or output leakage current –10 10 μA
C
IN
Input Capacitance (V
IN
= GND, f = 1.0 MHz) – 10 pF
C
OUT
Output Capacitance (V
IN
= GND, f = 1.0 MHz) – 10 pF
Notes:
1. I
CCS
standby current is specified for DATA pin that is pulled to V
CC
or GND.
Product Obsolete or Under Obsolescence