JQ1-5V

JQ
–4–
ASCTB185E 201509-T
High capacity type
4.-(1) Coil temperature rise (1 Form A type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
4.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A
Measured portion: Inside the coil
100 110 120 130 140 160 190180170150
10
20
30
40
50
0
Coil applied voltage, %V
Temperature rise, °C
3 A at 85°C
5 A at 85°C
3 A at 70°C
5 A at 70°C
100 110 120 130 140 160150
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, °C
3 A at 70°C
5 A at 70°C
5 A at 85°C
3 A at 85°C
5.-(1) Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1a-24V-F
Contact carrying current: 3 A, 5 A
5.-(2) Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1-24V-F
Contact carrying current: 3 A, 5 A 1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 3 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 3 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 3 A)
7 Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
6
4
7
3
2
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
3
4
5
7
6
2
1. Life curve
Ambient temperature: room temperature
2.-(1) Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V-F, 25 pcs.
2.-(2) Operate & release time (1 Form C type)
Tested sample: JQ1P-12V-F, 25 pcs.
100
10
1
2046810
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×10
4
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
80 100 120 150
2
0
4
6
8
Coil applied voltage, %V
Operate & release time, ms
Operate time
Release time
Min.
Min.
Max.
Max.
3.-(1) Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
3.-(2) Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
100 120 140 160 180
10
20
30
40
50
60
70
0
Coil applied voltage, %V
Temperature rise, °C
10 A at 70°C
10 A at 85°C
5 A at 70°C
5 A at 85°C
Coil applied voltage, %V
Temperature rise, °C
100 110 120 130 140 150 160
10
20
30
40
50
60
70
0
10 A at 70°C
10 A at 85°C
5 A at 70°C
5 A at 85°C
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
–5–
ASCTB185E 201509-T
DIMENSIONS
(mm inch)
4.-(1) Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1aP-24V-F
Contact carrying current: 5 A, 10 A
4.-(2) Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A 1 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
2 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
3 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
4 Allowable ambient temperature against
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
5 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 10 A)
6 Pick-up voltage with a hot-start condition
of 100%V on the coil (Carrying current: 5 A)
7 Pick-up voltage
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
4
7
6
3
2
20 30 40 50 60 70 80 90
0
100
200
300
400
Ambient temperature, °C
Coil applied voltage, %V
1
5
7
6
2
3
4
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
1 Form A
1 Form C
20
15.6
4.2
0.4
10.16 7.62 7.627.62
10
0.3
0.3
0.5 dia.
0.8
.787
.614
.165
.016
.400 .300 .300.300
.394
.012
.012
.020 dia. .031
4.2
0.4
20
15.6
10.16
5.08
.200
2.54
7.627.62
0.3 0.3
0.3
0.5 dia.
0.8
10
.165
.016
.787
.614
.400
.100
.300.300
.012 .012
.012
.020 dia.
.031
.394
Schematic (Bottom view)
1 Form A 1 Form C
Coil
COM N.O.
Coil
COM N.O.
N.C.
PC board pattern (Bottom view)
1 Form A 1FormC
Tolerance: ±0.1 ±.004
4-1.3 dia.
7.62
7.62
10.16
4-.051 dia.
.300
.300
.400
5-1.3 dia.
7.62
7.62
10.16
2.54
5-.051 dia.
.300
.300
.400
.100
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 5mm .197 inch:
Min. 5mm .197 inch:
Gener
al tolerance
±0.2 ±.008
±0.3 ±.012
±0.4 ±.016
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016
JQ
–6–
ASCTB185E 201509-T
SAFETY STANDARDS
NOTES
For Cautions for Use.
Item
UL/C-UL (Recognized) CSA (Certified) VDE (Certified) TÜV (Certified) SEMKO (Certified)
File No. Contact rating File No. Contact rating File No. Contact rating File No. Rating File No. Contact rating
Standard type
(5A) 1 Form A
E43028 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
LR26550 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
40011435 5A 250V AC (cos
φ
=0.4) B 11 04
13461 296
5A 250V AC (cos
φ
=0.4)
5A 30V DC (0ms)
817138 3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
Standard type
(5A) 1 Form C
E43028 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
LR26550 5A 125V AC
5A 277V AC
5A 30V DC
0.3A 110V DC
1
/
10
HP 125V AC
1
/
6
HP 277V AC
40011435 5A 250V AC (cos
φ
=0.4)
(N.O.)
3A 250V AC (cos
φ
=0.4)
(N.C.)
B 11 04
13461 296
5A 250V AC (cos
φ
=0.4)
5A 30V DC (0ms)
817138 3(2)A 125V AC
2(1)A 250V AC
5A 30V DC
High capacity type
(10A) 1 Form A
E43028 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/
6
HP 125V AC
1
/6HP 277V AC
LR26550 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/
6
HP 125V AC
1
/6HP 277V AC
40011435 10A 250V AC (cos
φ
=0.4) B 11 04
13461 296
10A 250V AC (cos
φ
=0.4)
5A 30V DC (0ms)
817138 5(3)A 250V AC
5A 30V DC
High capacity type
(10A) 1 Form C
E43028 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/
6
HP 125V AC
1
/
6
HP 277V AC
LR26550 10A 125V AC
8A 277V AC
5A 30V DC
0.3A 110V DC
1
/
6
HP 125V AC
1
/
6
HP 277V AC
40011435 (N.O.)
10A 250V AC (cos
φ
=0.4)
(N.C.)
3A 250V AC (cos
φ
=0.4)
B 11 04
13461 296
10A 250V AC (cos
φ
=0.4)
5A 30V DC (0ms)
817138 5(3)A 250V AC
5A 30V DC
Note about relay installation orientation
Top
Bottom
When installing with the relay terminals parallel to the ground, the contact terminals at
the bottom and the coil terminals at the top, component friction will occur after
numerous switching actions or due to vibration in the non-excitation state.
Since this may cause the relay to stop functioning when the pick-up voltage increases
even if the nominal voltage is applied, please do not install using this orientation.
Partly to Be Discontinued: 10A type (Made in Thailand)
Last time buy: September 30, 2016

JQ1-5V

Mfr. #:
Manufacturer:
Panasonic
Description:
RELAY GENERAL PURPOSE SPDT 5A 5V
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union