Document #: 38-07140 Rev. *I Page 4 of 15
Absolute Maximum Conditions
Supply Voltage to Ground Potential................–0.5V to +7.0V
DC Input Voltage (Except REF) ............–0.5V to V
DD
+ 0.5V
DC Input Voltage REF .........................................–0.5V to 7V
Storage Temperature ................................. –65°C to +150°C
Junction Temperature................................................. 150°C
Static Discharge Voltage
(per MIL-STD-883, Method 3015) ...........................> 2,000V
Operating Conditions for CY2305SC-XX and CY2309SC-XX Commercial Temperature Devices
Parameter Description Min Max Unit
V
DD
Supply Voltage 3.0 3.6 V
T
A
Operating Temperature (Ambient Temperature) 0 70 °C
C
L
Load Capacitance, below 100 MHz – 30 pF
C
L
Load Capacitance, from 100 MHz to 133 MHz – 10 pF
C
IN
Input Capacitance – 7 pF
t
PU
Power up time for all V
DD
s to reach minimum specified voltage
(power ramps must be monotonic)
0.05 50 ms
Electrical Characteristics for CY2305SC-XX and CY2309SC-XX Commercial Temperature
Devices
Parameter Description Test Conditions Min Max Unit
V
IL
Input LOW Voltage
[5]
–0.8V
V
IH
Input HIGH Voltage
[5]
2.0 – V
I
IL
Input LOW Current V
IN
= 0V – 50.0 μA
I
IH
Input HIGH Current V
IN
= V
DD
–100.0μA
V
OL
Output LOW Voltage
[6]
I
OL
= 8 mA (–1)
I
OH =
12
mA (–1H)
–0.4V
V
OH
Output HIGH Voltage
[6]
I
OH
= –8 mA (–1)
I
OL
= –12 mA (–1H)
2.4 – V
I
DD
(PD mode) Power Down Supply Current REF = 0 MHz – 25.0 μA
I
DD
Supply Current Unloaded outputs at 66.67 MHz,
SEL inputs at V
DD
– 32.0 mA
Switching Characteristics for CY2305SC-1 and CY2309SC-1 Commercial Temperature
Devices
Parameter
[7]
Name Test Conditions Min Typ. Max Unit
t1 Output Frequency 30-pF load
10 pF load
10
10
– 100
133.33
MHz
MHz
t
DC
Duty Cycle
[6]
= t
2
÷ t
1
Measured at 1.4V, F
out
= 66.67
MHz
40.0 50.0 60.0 %
t3
Rise Time
[6]
Measured between 0.8V and
2.0V
– – 2.50 ns
t
4
Fall Time
[6]
Measured between 0.8V and
2.0V
– – 2.50 ns
t
5
Output to Output Skew
[6]
All outputs equally loaded – 85 250 ps
t
6A
Delay, REF Rising Edge to
CLKOUT Rising Edge
[6]
Measured at V
DD
/2 – 0 ±350 ps
Notes
5. REF input has a threshold voltage of V
DD
/2.
6. Parameter is guaranteed by design and characterization. Not 100% tested in production.
[+] Feedback