PD-4
REV.: 2/2016 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP15-FW
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E196683
UL60950-1 1st Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
(9)
with external filter EN55022, Class A or B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
(10)
Surge Immuntity
(10)
Immunity to conducted disturbances, induced by radio-frequency fields
Air ±8kV and Contact ±6kV
10 V/m
±2kV
±1kV
10 Vr.m.s
EN61000-4-2, Criteria B
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
without derating
with derating
-40°C to +76°C
-40°C to +105°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance
Natural convection (20LFM)
Natural convection (20LFM) with Heat-sink
12°C/Watt
10°C/Watt
Operating Humidity 5% - 95% RH
Thermal Shock MIL-STD-810F
Vibration MIL-STD-810F
MTBF
MIL-HDBK-217F, Full Load
Bellcore TR-NWT-000332
(7)
2430 x 10³ hours
2350 x 10
3
hours
-40 60 80
105
12040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
-40 60
85
80
100
120
105
40
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
Derating Graph
(8)
Notes:
Note7: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com.
RP15-4805SFW
RP15-4805SFW with Heat-sink
Notes:
Note9: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below.
Note10: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Recom
suggests: Nippon chemi-con KY series, 220µF/100V.