Surge arrester B88069X5020T103
2-electrode arrester M51-C90XG
PPD AB PD / PPD AB PM Issue 08 / 2011-12-16
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Very small size
High current rating
Very fast response time
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Modem
XDSL-splitter
Data lines
Tuner
Antenna
Electrical specifications
DC spark-over voltage
1) 2)
90
20
V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 400
< 300
< 600
< 550
V
V
V
V
Service life
10 operations 50 Hz, 1 s 5 A
1 operation 50 Hz, 0.18 s (9 cycles) 10 A
10 operations 8/20 µs 5 kA
1 operation 8/20 µs 7.5 kA
1 operation 10/350 µs 0.5 kA
300 operations 10/1000 µs 100 A
Insulation resistance at 50 V
DC
> 1
G
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 15
~ 0.8
~ 60
V
A
V
Weight ~ 1 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, blue negative
90 YY O
90 - Nominal voltage
YY - Year of production
O - Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12, IEC 61663-2 and IEC 61643-311