Applications
Overcurrent protection for telecom applications
Suitable for line card applications e.g. POTS, access networks, customer premises
equipment (CPE) or integrated voice data (IVD)
Features
Compliant with ITU-T standards
basic-level lightning surges (10/700 µs)
basic-level power induction (600 V, 1 A, 0.2 s)
power contact criteria A/B (230 V, 15 min.)
Suitable for continuous connection to mains voltages of 110/230 V AC
in tripped (high-ohmic) condition
UL approval for Gamma I version to UL 1434 (file number E69802)
Matching available with narrow resistance tolerance
Tight resistance matching maintained after switching
Negligible resistance drift after reflow soldering or switching
Marked with type designation and date code
RoHS-compatible
Options
Alternative tolerances and resistances on request
Delivery mode
Blister tape, 330-mm reel with 16-mm (Gamma I) or 24-mm tape (Gamma L), taping to
IEC 60286-3
General technical data
Max. operating voltage V
max
245 V AC
Operating temperature range (V = 0) T
op
20/+125 °C
Operating temperature range (V = 230 V) T
op
0/+70 °C
Overcurrent protection for telecom
Single SMDs
Page 2 of 11Please read Cautions and warnings and