MPXAZ4100A
Rev 1, 05/2005
Freescale Semiconductor
Technical Data
© Freescale Semiconductor, Inc., 2005. All rights reserved.
Integrated Silicon Pressure Sensor
for Manifold Absolute Pressure
Applications On-Chip Signal
Conditioned, Temperature
Compensated and Calibrated
The Freescale MPXAZ4100A series Manifold Absolute Pressure (MAP)
sensor for engine control is designed to sense absolute air pressure within the
intake manifold. This measurement can be used to compute the amount of fuel
required for each cylinder. The small form factor and high reliability of on-chip
integration makes the Freescale MAP sensor a logical and economical choice for
automotive system designers.
The MPXAZ4100A series piezoresistive transducer is a state-of-the-art,
monolithic, signal conditioned, silicon pressure sensor. This sensor combines
advanced micromachining techniques, thin film metallization, and bipolar
semiconductor processing to provide an accurate, high level analog output signal
that is proportional to applied pressure.
Figure 1 shows a block diagram of the internal circuitry integrated on a
pressure sensor chip.
Features
• Resistant to high humidity and common automotive media
• 1.8% Maximum Error Over 0° to 85°C
• Specifically Designed for Intake Manifold Absolute
Pressure Sensing in Engine Control Systems
• Ideally Suited for Microprocessor or Microcontroller Based Systems
• Temperature Compensated Over –40°C to +125°C
• Durable Thermoplastic (PPS) Surface Mount Package
Typical Applications
• Manifold Sensing for Automotive Systems
• Also Ideal for Non-Automotive Applications
ORDERING INFORMATION
Device
Type
Options
Case
No.
MPX Series
Order No.
Packing
Options
Device
Marking
SMALL OUTLINE PACKAGE (MPXAZ4100A SERIES)
Basic
Elements
Absolute,
Element Only
482
MPXAZ4100A6U
Rails
MPXAZ4100A
Absolute,
Element Only
482
MPXAZ4100A6T1
Tape & Reel
MPXAZ4100A
Ported
Elements
Absolute, Axial
Port
482A
MPXAZ4100AC6U
Rails
MPXAZ4100A
Absolute, Axial
Port
482A
MPXAZ4100AC6T1
Tape & Reel
MPXAZ4100A
MPXAZ4100A
SERIES
INTEGRATED
PRESSURE SENSOR
20 TO 105 kPA (2.9 TO 15.2 psi)
0.3 TO 4.9 V OUTPUT
MPXA4100A6U/6T1
CASE 482-01
MPXA4100AC6U/AC6T1
CASE 482A-01
PIN NUMBER
(1)
1. Pins 1, 5, 6, 7, and 8 are internal device
connections. Do not connect to external
circuitry or ground. Pin 1 is noted by the
notch in the lead.
1 N/C 5 N/C
2 V
S
6 N/C
3 GND 7 N/C
4 V
OUT
8 N/C
SMALL OUTLINE PACKAGES