SCRH64
500 Bayview Avenue, Inwood, NY 11096
Toll Free 866-239-5777 • Tel 516-239-5777 • Fax 516-239-7208
www.signaltransformer.com Sales@signaltransformer.com • techhelp@signaltransformer.com
122
Click here for QUANTITY PER REEL & PACKING INFORMATION
●
1. Magnetically shielded construction
2 Excellent Power Density
3 Engineered to Provide High Efficiency
Part Number
Inductance
(uH)
(1)
Test
Frequency
DC Resistance
(Ω MAX)
(2)
Saturation
Current
Temperature
Current
SCRH64-100 10 1KHZ 0.12 1.35 2.00
SCRH64-150 15 1KHZ 0.18 1.11 1.62
SCRH64-220 22 1KHZ 0.27 0.91 1.30
SCRH64-330 33 1KHZ 0.33 0.74 1.05
SCRH64-470 47 1KHZ 0.52 0.62 0.90
SCRH64-680 68 1KHZ 0.63 0.51 0.80
SCRH64-101 100 1KHZ 1.03 0.42 0.64
SCRH64-151 150 1KHZ 1.68 0.35 0.51
SCRH64-221 220 1KHZ 2.08 0.29 0.46
SCRH64-331 330 1KHZ 2.67 0.23 0.42
SCRH64-471 470 1KHZ 3.93 0.20 0.38
SCRH64-681 680 1KHZ 7.32 0.17 030
SCRH64-102 1000 1KHZ 9.26 0.14 0.21
(1). Inductance tolerance ±20% tested at 0.25V, 0ADC and 25℃
(2). DCR measured at 25℃.
(3). The DC current at which the inductance decreases by 25% from its initial value.
(4). The DC current that results in a 40℃ temperature rise from 25℃ambient.
(3)
(4)
XXX
MARKING
1
10
100
100
1000
10000
10
BCRH64 I nduct ance decr ease by cur r ent
I nduct ance( uH)
100000
DC c u r r e n t ( mA)
1000
10000
100
101
102
500
1000 2000
1500
3500
3000
2500
0
Temper at ur e r i se ℃
BCRH64 Temper at ur e r i se by cur r ent
DC c u r r e n t ( mA)
80
50
70
40
60
30
20
10
102
101
100
SCRH64 Inductance decrease by current
DC current (mA)
DC current (mA)
SCRH64 Temperature rise by current
Custom versions available upon request.
©2011 Signal Transformer –Specification subject to change without notice. 07.11