PDU3V20D354A

Requires Tripp Lite 3-phase auto-transfer switch (ATS) PDU (sold separately).
PDU330AT6L15
PDU330AT6L1530
PDU330AT6L2130
PDU330AT6H50
8.6/12.6kW 3-Phase Vertical PDU Strip, 208V
Outlets (42 C13 & 12 C19), 0U Rack-Mount,
Accessory for Select ATS PDUs
MODEL NUMBER: PDU3V20D354A
Required rack-mounted vertical outlet strip accessory for select Tripp Lite 3-phase auto-transfer switch
(ATS) PDUs. Distributes AC power to high-density equipment racks in data centers and server rooms.
Description
The PDU3V20D354A 8.6/12.6kW 3-Phase Vertical Power Distribution Unit (PDU) Outlet Strip is a
required accessory option for Tripp Lite’s PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530,
PDU350AT6H50 and other 3-phase auto-transfer switch (ATS) PDUs that specify compatibility with this
model. It’s ideal for high-density equipment racks in data centers and server rooms.
When used with 208V ATS models with a 35A input rating (such as PDU350AT6H50), the
PDU3V20D354A supports up to 12.6kW total output with 20A maximum full balanced load per phase
combination output bank (L1-L2, L2-L3, L3-L1). When used with 208V ATS models with a 24A input rating
(such as PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15), it supports up to 8.6kW total output
with 13.9A maximum balanced load per phase combination output bank.
The 42 C13 and 12 C19 single-phase outlets receive power from the connected ATS PDU. The outlets
are interlaced to help you balance loads by spreading connections across the phase combinations (L1-L2,
L2-L3, L3-L1) throughout the rack. Each outlet is numbered and color-coded to help you keep track of
connected devices and which phase combination powers each. The 2.5-foot power cord with 8-position
plug connects directly to the PDU’s rear receptacle.
Highlights
Required for select Tripp Lite 3-
phase ATS PDUs
Offers 42 C13 and 12 C19
single-phase outlets
Supports up to 8.6 or 12.6kW
total output (depends on ATS
PDU)
Simplifies load balancing with
interlaced, color-coded outlets
Supports 0U toolless vertical
rack mounting
Package Includes
PDU3V20D354A 8.6/12.6kW 3-
Phase Vertical PDU Outlet Strip
1 / 4
Specifications
The PDU3V20D354A’s rugged all-metal housing mounts in compatible racks in seconds with no tools
needed. Vertical 0U installation reduces cord clutter and improves airflow through the rack.
Features
Required Accessory for Select Tripp Lite ATS PDUs
Compatible with PDU330AT6L15, PDU330AT6L2130, PDU330AT6L1530, PDU350AT6H50 and other
select Tripp Lite 3-phase ATS PDUs
Ideal for high-density equipment racks in data centers and server rooms
Supports up to 12.6kW total output with 20A maximum per output bank when connected to 208V ATS
models with a 35A input rating (such as PDU350AT6H50)
Supports up to 8.6kW total output with 13.9A maximum per output bank when connected to 208V ATS
models with a 24A input rating (such as PDU330AT6L2130, PDU330AT6L1530 or PDU330AT6L15)
Heavy-duty 2.5 ft. power cord plugs directly into the ATS PDU with a Unique 8-position plug
Features 42 C13 and 12 C19 Interlaced C13 Outlets
Single-phase outlets are interlaced to help you balance loads by spreading connections across the
phase combinations (L1-L2, L2-L3, L3-L1) throughout the rack
Numbered and color-coded for easy identification of connected devices and which phase combination
output bank powers them
Installs Easily in 0U of Rack Space
Preinstalled mounting buttons for toolless vertical rack-mounting in compatible racks
Saves rack space, improves airflow and reduces cord clutter by locating outlets closer to connected
devices
Preinstalled ground screw for connecting devices that require chassis ground
Heavy-duty all-metal housing provides durability and reliability in demanding high-density rack
environments
OVERVIEW
UPC Code 037332190444
Accessories Type 0U Strip for 3-Phase ATS PDU
OUTPUT
Output Capacity Details Supports up to 12.6kW total output; 20A max per output phase (L1-L2, L2-L3, L3-L1) when used with 35A max 208V
input ATS models (such as PDU350AT6H50); Supports up to 8.6kW total output; 13.9A max per output phase (L1-
L2, L2-L3, L3-L1) when used with 24A max 208V input ATS models (such as PDU330AT6L2130, PDU330AT6L1530
and PDU330AT6L15); All configurations: 16A max per C19 outlet, 12A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (42) C13; (12) C19
2 / 4
Output Nominal Voltage 200; 208; 220; 230; 240
Overload Protection n/a
INPUT
PDU Input Voltage 200; 208; 220; 230; 240
Maximum Input Amps 35
Input Cord Details Includes 7 conductor input plug for use with compatible Tripp Lite ATS PDU products only
Input Cord Length (ft.) 2.5
Input Cord Length (m) 0.76
Input Phase 3-Phase
PHYSICAL
Shipping Dimensions (hwd / in.) 76.400 x 6.500 x 5.100
Shipping Dimensions (hwd / cm) 194.06 x 16.51 x 12.95
Shipping Weight (lbs.) 14.4600
Shipping Weight (kg) 6.56
Unit Dimensions (hwd / in.) 70 x 2.2 x 2.22
Unit Dimensions (hwd / cm) 177.8 x 5.59 x 5.64
Unit Weight (lbs.) 9.26
Unit Weight (kg) 4.20
Material of Construction Metal
Form Factors Supported Vertical rackmount installation supported with toolless mounting in button-mount compatible racks
PDU Form Factor Vertical (0U)
ENVIRONMENTAL
Operating Temperature Range 0 to 50C (32 to 122F)
Storage Temperature Range -15C to 60C (5 to 140F)
Relative Humidity 5-95% non-condensing
Operating Elevation (ft.) 0-10,000
Operating Elevation (m) 0-3000
CERTIFICATIONS
Certifications Tested to UL60950-1 (USA), CSA (Canada), NOM (Mexico), FCC Class A (Emissions), ROHS
WARRANTY
Product Warranty Period
(Worldwide)
2-year limited warranty
3 / 4