MKP338 2 X2
www.vishay.com
Vishay BCcomponents
Revision: 21-Sep-16
10
Document Number: 28119
For technical questions, contact: rfi@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
CHARACTERISTICS
Capacitance as a function of ambient temperature
(typical curve)
Tangent of loss angle as a function of frequency
(typical curve)
Max. RMS voltage as a function of frequency
(typical curve)
Impedance as a function of frequency
(typical curve)
Resonant frequency as a function of capacitance
(typical curve)
Max. RMS current as a function of frequency
(typical curve)
typical
- 50
Δ
C/C
(%)
2
- 2
- 4
- 6
0
0 50 100T
amb
(°C)
4
max.
min.
Dissipation
factor (x 10
-4
)
C > 1 µF
C
10 nF
10 nF < C 47 nF
47 nF < C 220 nF
220 nF < C 1 µF
10
3
10
2
10
1
10
0
10
1
10
2
10
3
10
4
10
5
f (Hz)
T
amb
110 °C
AC voltage
(V)
10
3
10
2
10
1
f (Hz)
10
1
10
2
10
3
10
4
10
5
3300 nF
10 nF
47 nF
100 nF
470 nF
1000 nF
4.7 nF
1 nF
Impedance
(Ω)
10
3
10
1
10
-2
10
0
f (Hz)
10
6
10
4
10
5
10
7
10
8
10
-1
X2
10
2
10
1
10
0
10
-1
1 10
100 1000
10 000
f (MHz)
C (nF)
AC current
(mA)
10
4
10
2
10
0
10
1
f (Hz)
10
1
10
2
10
3
10
4
10
5
10
-1
T
amb
110 °C
470 nF
100 nF
47 nF
10 nF
1000 nF
1nF
3300 nF
4.7 nF
MKP338 2 X2
www.vishay.com
Vishay BCcomponents
Revision: 21-Sep-16
11
Document Number: 28119
For technical questions, contact: rfi@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Insulation resistance
APPLICATION NOTES
For X2 electromagnetics interference suppression in standard across the line applications (50 Hz/60 Hz) with a maximum
mains voltage of 310 V
AC
.
For series impedance applications we refer to application note www.vishay.com/doc?28153
For capacitors connected in parallel, normally the proof voltage and possibly the rated voltage must be reduced. For
information depending of the capacitance value and the number of parallel connections contact: rfi@vishay.com
These capacitors are not intended for continuous pulse applications. For these situations, capacitors of the AC and pulse
programs must be used.
The maximum ambient temperature must not exceed 105 °C (125 °C for less than 1000 h) for C 470 nF and 110 °C for
C > 470 nF
Rated voltage pulse slope:
If the pulse voltage is lower than the rated voltage, the values of the specific reference data can be multiplied by 435 V
DC
and
divided by the applied voltage.
INSPECTION REQUIREMENTS
General Notes
Sub-clause numbers of tests and performance requirements refer to the “Sectional Specification, IEC Publication
IEC 60384-14 ed-4 (2013) and Specific Reference Data.”
GROUP C INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS
SUB-GROUP C1A PART OF
SAMPLE OF SUB-GROUP C1
4.1 Dimensions (detail) As specified in chapters “General Data” of this
specification
Initial measurements Capacitance
Tangent of loss angle:
For C 1 µF at 10 kHz
For C > 1 µF at 1 kHz
4.3 Robustness of terminations Tensile: Load 10 N; 10 s
Bending: Load 5 N; 4 x 90°
No visible damage
4.4 Resistance to soldering heat No pre-drying
Method: 1A
Solder bath: 280 °C ± 5 °C
Duration: 10 s
10
6
10
5
10
4
0
20 40 60
80
100
T
amb
(°C)
RC (s)
MKP338 2 X2
www.vishay.com
Vishay BCcomponents
Revision: 21-Sep-16
12
Document Number: 28119
For technical questions, contact: rfi@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
SUB-GROUP C1A PART OF
SAMPLE OF SUB-GROUP C1
4.19 Component solvent resistance Isopropylalcohol at room temperature
Method: 2
Immersion time: 5 min ± 0.5 min
Recovery time:
Min. 1 h, max. 2 h
4.4.2 Final measurements Visual examination No visible damage
Legible marking
Capacitance |C/C| 5 % of the value measured initially
Tangent of loss angle Increase of tan :
0.008 for: C 1 µF or
0.005 for: C > 1 µF
Compared to values measured initially
Insulation resistance As specified in section “Insulation resistance” of
this specification
SUB-GROUP C1B PART OF
SAMPLE OF SUB-GROUP C1
Initial measurements Capacitance
Tangent of loss angle:
For C 1 µF at 10 kHz
For C > 1 µF at 1 kHz
4.20 Solvent resistance of the
marking
Isopropylalcohol at room temperature
Method: 1
Rubbing material: Cotton wool
Immersion time: 5 min ± 0.5 min
No visible damage
Legible marking
4.6 Rapid change of temperature A = - 55 °C
B = + 110 °C
5 cycles
Duration t = 30 min
4.6.1 Inspection Visual examination No visible damage
4.7 Vibration (see note 3.1) Mounting: See section “Mounting” of this
specification
Procedure B4
Frequency range: 10 Hz to 55 Hz.
Amplitude: 0.75 mm or
Acceleration 98 m/s
(whichever is less severe)
Total duration 6 h
4.7.2 Final inspection Visual examination No visible damage
4.9 Shock (see note 3) Mounting: See section “Mounting” for more
information
Pulse shape: Half sine
Acceleration: 490 m/s
Duration of pulse: 11 ms
4.9.2 Final measurements Visual examination No visible damage
Capacitance |C/C| 5 % of the value measured initially
Tangent of loss angle Increase of tan :
0.008 for: C 1 µF or
0.005 for: C > 1 µF
Compared to values measured initially
Insulation resistance As specified in section “Insulation resistance” of
this specification
GROUP C INSPECTION REQUIREMENTS
SUB-CLAUSE NUMBER AND TEST CONDITIONS PERFORMANCE REQUIREMENTS

BFC233820335

Mfr. #:
Manufacturer:
Vishay
Description:
Safety Capacitors 3.3uF 20% 310volts
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union