PLC-OSP-…/24DC/3RW
102490_en_01 PHOENIX CONTACT 2
2Ordering Data
3 Technical Data
PLC INTERFACE
Description Type Order No. Pcs./Pck.
Single-channel optocoupler for railway applications, 24 V DC input voltage,
with spring-cage connection, for mounting on
3
PLC-OSP- 24DC/24DC/3RW 2980513 10
Single-channel optocoupler for railway applications, 110 V DC input voltage,
with spring-cage connection, for mounting on
3
PLC-OSP-110DC/24DC/3RW 2980526 10
For the protection of input and output, inductive loads must be dampened with an effective protective circuit.
Accessories
Description Type Order No. Pcs./Pck.
Insulating plate PLC-ATP BK 2966841 25
For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com.
Input Data ...24DC... ...110DC...
Nominal input voltage U
N
1
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
24 V DC 110 V DC
Permissible range (with reference to U
N
) 0.7 ... 1.25 x U
N
(t < 1 s = 0.6 ... 1.40 x U
N
)
Typical input current at U
N
8.5 mA 3 mA
Switch-on threshold U
ON
≥ 0.6 x U
N
Switch-off threshold U
OFF
≤ 0.3 x U
N
Typical response time at U
N
40 μs 80 μs
Typical release time at U
N
200 μs 600 μs
Transmission frequency at U
N
300 Hz 100 Hz
Input circuit Protection against polarity reversal
Status indicator Yellow LED
The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages
greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for
potential bridging) and for safe isolation between adjacent modules.
Output Data ...24DC... ...110DC...
Nominal output voltage U
N
24 V DC
Permissible range (with reference to U
N
) 3 V DC ... 33 V DC (t < 1 s = 1.40 x U
N
)
Limiting continuous current 3 A (see "Derating Curve" on page 3)
Voltage drop at maximum limiting continuous current < 200 mV
Output configuration 2-wire floating
Output circuit Protection against polarity reversal, surge protection
Surge voltage limitation > 33 V DC