Basic Switches DT Series
Double-pole Double-throw
66HoneywellSensingandControlForapplicationhelp:call1-800-537-6945.
FEATURES
1
Two independent single-pole double-
throw circuits on one housing
1
Design permitting several wiring
combinations
1
Savings in space and weight
1
Mounting interchangeability with type
Z switches
1
Temperature tolerance to +180°F
(82
°C)
1
UL recognized, CSA certified
AVAILABLE TERMINALS
B6
6-32 UNC H .188N
(No. 5 pan head screws)
A7
4-40 UNC H .125N
Screws with lockwashers.
Fiberglas insulator isolates
terminals and prevents
accidental shorting.
ELECTRICAL RATING
Electrical Data and
Circuitry UL Codes
Double-pole
double-throw
J 10 amps, 125 or 250 vac;
0.3 amp, 125 vdc; 0.15 amp,
250 vdc.
UL Code L59
DOUBLE-POLE
DOUBLE THROW
ORDER GUIDE
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position.
O.F. R.F. P.T. D.T. max.
Electrical max. min. max. O.T. min. O.P.*
Data and newtons newtons mm mm mm mm
Catalog Listing Description UL Code ounces ounces inches inches inches inches
DT-2R-A7
MS25008-1
Pin plunger 10 Amps 3,34-5,56 0,56 1,91 0,13 1,02-1,52 15,6
J 12-20 2 .075 .005 .040-.060 .615±.015
Dim. Dwg. Fig. 1
DT-2RS1-A7
Straight plunger 10 Amps 3,34-5,56 0,28 1,91 0,51 1,02-1,52 28,2±0,38
J 12-20 1 .075 .020 .040-.060 1.11±.015
Dim. Dwg. Fig. 9
DT-2RV3-A7
Straight lever
Reversed lever
position
10 Amps 1,11-1,95 0,14 6,86 0,25 2,92-4,83 18,3
J 4-7 0.5 .270 .010 .115-.190 .719
Dim. Dwg. Fig. 3
DT-2RV-A7
Straight lever 10 Amps 0,97-1,67 0,28 25,4 1,57 12,4-19,2 21,8
J 3.5-6 1 1 .062 .490-.755 .859
Dim. Dwg. Fig. 2
Except where stated * ±0,76 mm
±.030 in.