littelfuse.com© 2015 Littelfuse Revised: 10/16/15
Specifications are subject to change without notice.
HA15-2 15.2mm Sub-miniature HV Reed Switch
Description
The HA15-2 Reed Switch is a sub-miniature, normally open switch with a
15.24mm long x 2.28mm diameter (0.600” x 0.090”) glass envelope and capable
of high voltage switching of 265Vac at 10VA. It has high insulation resistance of
10
10
ohms minimum and contact resistance less than 100 milli-ohms. It can
handle light inductive loads with no suppression circuitry and switch European
mains voltage.
Agency Approvals
Agency Agency File Number Ampere-Turns Range
E47258
E471070
17-33 AT
DEMKO 14 ATEX 1393U 17-33 AT
Switch Type
Contact Form A (SPST-NO)
Materials
Body: Glass
Leads: Tin-plated Ni-Fe wire
Axial Lead Reed Switches
Features
• Sub-miniature normally
open switch
• Capable of switching 100-265Vac
or 0.3A up to 20VA loads outside of
this window is rated 10W max (see
Electrical Ratings)
• Minimum voltage breakdown
400Vdc (17-23AT) and 450Vdc
(22+ AT)
• Available sensitivity range
17-33 AT
Benefits
• Hermetically sealed switch
contacts are not affected by and
have no effect on their external
environment
• Capable of switching European
mains voltage
• Zero operating power required for
contact closure
Applications
• Reed Relays
• Security
• Limit Switching
• Office Equipment
• Light Inductive Loads
• European Mains Voltage Switching
Dimensions
Dimensions in mm (inch)
Low Power > HA15-2
RoHS
Note: SPST-NO = Single-pole, single-throw, normally open
Electrical Ratings
Sensitivity
6
17-23 22+
Contact Rating
1
W/VA - max.
20W for
100-265 VAC loads
10W for all other loads
Voltage
3
Switching
2
Breakdown
4
Vdc - max.
Vac - max.
Vdc - min.
200
265 rms
400
200
265 rms
450
Current
3
Switching
2
Carry
Adc - max.
Aac - max.
Adc - max.
0.40
0.30
1.4
0.50
0.35
1.5
Resistance
Contact, Initial
Insulation
Ω - max.
Ω - min.
0.100
10
10
0.100
10
10
Capacitance Contact pF - typ. 0.2 0.2
Temperature
Operating
Storage
5
°C
°C
-20 to +125
-65 to +125
-20 to +125
-65 to +125
Notes:
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.
3. Electrical Load Life Expectancy - Contact Littelfuse with voltage and current values along with type of load.
4. Breakdown Voltage - Per MIL-STD-202, Method 301.
5. Storage Temperature - Long time exposure at elevated temperature may degrade solderability of the lead.
6. Rating Sensitivity - The value at which contact ratings and operating characteristics are determined. Derating may be required for lower values.
20.19
(.795) REF.
12.19
(.480) MIN.
15.24
(.600) MAX.
40.38
2.28
(.090) DIA. MAX.
(.020) DIA. REF.
CL OF OVERLAP