Technical Data Sheet
Calibration Adaptor
RPC-N 75 Ω Plug – BNC 75 Ω Plug
P5S171-S2AS3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 3
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt
● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Frequency DC to 12 GHz
Return loss ≥ 30 dB, DC to 4 GHz
≥ 25 dB, 4 GHz to 8 GHz
≥ 15 dB, 8 GHz to 12 GHz
Mechanical data
Mating cycles ≥ 500
RPC-N 75 Ω BNC 75 Ω
Maximum torque 1.70 Nm
Recommended torque 1.10 Nm
Gauge 5.28 mm to 5.36 mm 5.31 mm to 5.38 mm
General standard definition
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this calibration standard. The different models, units, and terms used will depend on the VNA type and they
will have to be entered into the VNA. All values are based on typical geometry and plating.
Offset Z
o
/ Impedance / Z
o
75 Ω
Offset Delay 135.761 ps
Length (electrical) / Offset Length 40.70 mm
Offset Loss 1.2 GΩ/s
Loss 0.0094 dB/
GHz
Environmental data
Operating temperature range
1
+20 °C to +26 °C
Rated temperature range of use
2
0 °C to +50 °C
Storage temperature range -40 °C to +85 °C
RoHS compliant
1
Temperature range over which these specifications are valid.
2
This range is underneath and above the operating temperature range, within the open circuit is fully functional
and could be used without damage.