3
IDT74FCT162823AT/CT
FAST CMOS 18-BIT REGISTER
INDUSTRIAL TEMPERATURE RANGE
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
IODL Output LOW Current VCC = 5V, VIN = VIH or VIL, VO = 1.5V
(3)
60 115 200 mA
IODH Output HIGH Current VCC = 5V, VIN = VIH or VIL, VO = 1.5V
(3)
–60 –115 –200 mA
V
OH Output HIGH Voltage VCC = Min. IOH = –24mA 2.4 3.3 — V
VIN = VIH or VIL
VOL Output LOW Voltage VCC = Min. IOL = 24mA — 0.3 0.55 V
VIN = VIH or VIL
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
VIH Input HIGH Level Guaranteed Logic HIGH Level 2 — — V
VIL Input LOW Level Guaranteed Logic LOW Level — — 0.8 V
IIH Input HIGH Current (Input pins)
(4)
VCC = Max. VI = VCC ——±1µA
Input HIGH Current (I/O pins)
(4)
——±1
IIL Input LOW Current (Input pins)
(4)
VI = GND — — ±1
Input LOW Current (I/O pins)
(4)
——±1
IOZH High Impedance Output Current VCC = Max. VO = 2.7V — — ±1 µA
IOZL (3-State Output pins)
(4)
VO = 0.5V — — ±1
VIK Clamp Diode Voltage VCC = Min., IIN = –18mA — –0.7 –1.2 V
IOS Short Circuit Current VCC = Max., VO = GND
(3)
–80 –140 –250 mA
VH Input Hysteresis — — 100 — mV
ICCL Quiescent Power Supply Current VCC = Max — 5 500 µ A
I
CCH VIN = GND or VCC
ICCZ
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Industrial: TA = –40°C to +85°C, VCC = 5.0V ±10%
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
4. This test limit for this parameter is ±5µA at TA = –55°C.
OUTPUT DRIVE CHARACTERISTICS