The OKX-T/10 and -T/16 series are miniature
SIP non-isolated Point-of-Load (POL) DC/DC power
converters for embedded applications. The module
is fully compatible with Distributed-power Open
Standards Alliance (DOSA) industry-standard
specifi cations (www.dosapower.com). Applications
include powering CPU’s, datacom/telecom systems,
programmable logic and mixed voltage systems.
The wide input range is 2.4 to 5.5 Volts DC. Two
maximum output currents are offered, 10 Amps
(T/10 models) or 16 Amps (T/16 models). Based
on fi xed-frequency synchronous buck converter
switching topology, the high power conversion
effi cient Point of Load (POL) module features pro-
grammable output voltage and On/Off control. An
optional Sequence/Tracking input allows controlled
ramp-up and ramp-down outputs. The Sense input
provides load compensation. These converters also
include under voltage lock out (UVLO), output short
circuit protection, over-current and over tempera-
ture protections.
These units are designed to meet all standard
UL/EN/IEC 60950-1 safety certifi cations and RoHS-
6 hazardous substance compliance.
PRODUCT OVERVIEW
Figure 1. OKX2-T/10, -T/16
Connection Diagram
Note: Murata Power Solutions strongly recommends an external input fuse, F1.
See specifi cations.
External
DC
Power
Source
F1
On/Off
Control
CommonCommon
Sequence/Tracking (optional)
Open = On
Closed = Off
+Vin +Vout
Trim
Sense
Controller
Reference and
Error Amplifier
t4XJUDIJOH
t'JMUFST
t$VSSFOU4FOTF
(Positive
On/Off)
FEATURES
Non-isolated SIP POL DC/DC power module
2.4-5.5Vdc input voltage range
Programmable output voltage from 0.7525-3.63Vdc
10 Amp (T/10) or 16 Amp (T/16) output current
models
Drives 1000 µF ceramic capacitive loads
High power conversion effi ciency 95% at 3.3 Vout
Outstanding thermal derating performance
Over temperature and over current protection
On/Off control, Sense and optional Sequence/
Tracking input
UL/EN/IEC 60950-1 safety
Industry-standard (DOSA) SIP format
RoHS-6 hazardous substance compliance
Typical unit
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
MDC_OKX_T10T16-W5 Series.A06 Page 1 of 13
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
 
PART NUMBER STRUCTURE
The input voltage range must be 0.5V greater than the output voltage.
All specifications are at nominal line voltage, Vout=nominal (3.3V for W5 models) and full load, +25 deg.C.
unless otherwise noted.
Output capacitors are 1 µF ceramic and 10 µF electrolytic in parallel. Input cap is 22 µF. See detailed specifications.
I/O caps are necessary for our test equipment and may not be needed for your application.
Use adequate ground plane and copper thickness adjacent to the converter.
Ripple and Noise (R/N) is shown at Vout=1V. See specs for details.
PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE
Model Number
Output Input
Effi ciency
On/Off
Logic
Sequence/
Tracking
Package C86,
Pinout P84
VOUT
(Volts)
IOUT
(Amps
max)
Power
(Watts)
R/N
(mVp-p)
Max.
Regulation (Max.)
Vin Nom.
(Volts)
Range
(Volts)
Iin,
no load
(mA)
Iin,
full load
(Amps)
Case
Dimensions are
in inches (mm)
Line Load Min. Typ.
OKX-T/10-W5P-C 0.7525-3.63 10
33 25 ±0.2%
±0.5%
5 2.4-5.5
80
6.91 94.0% 95.5%
Pos. no
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX-T/10-W5N-C 0.7525-3.63 10 5 2.4-5.5
Neg. no
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX2-T/10-W5P-C 0.7525-3.63 10 5 2.4-5.5
Pos. yes
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX2-T/10-W5N-C 0.7525-3.63 10 5 2.4-5.5
Neg yes
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX-T/16-W5P-C 0.7525-3.63 16
52.8 30 ±0.3%
5 2.4-5.5
11.12 93.0% 95.0%
Pos. no
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX-T/16-W5N-C 0.7525-3.63 16 5 2.4-5.5
Neg. no
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX2-T/16-W5P-C 0.7525-3.63 16 5 2.4-5.5
Pos. yes
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX2-T/16-W5N-C 0.7525-3.63 16 5 2.4-5.5
Neg. yes
2.0x0.5x0.37
(50.8x12.7x9.4)
Okami Non-isolated PoL
Maximum Rated Output
Current in Amps
Sequence/Tracking
Blank = Not installed, delete pin 9
2 = Installed, add pin 9
SIP Mount
Trimmable Output
Voltage Range
W5 Models = 0.7525-3.63V
Input Voltage Range
W5 = 2.4-5.5V
On/Off Logic
P = Positive Logic
N = Negative Logic
XOK 2 -/ W5-T 16 C-
RoHS Hazardous Substance Compliance
C = RoHS-6 (does not claim EU RoHS
exemption 7b–lead in solder)
P
Note: Some model number combinations
may not be available. See Ordering Guide
above. Contact Murata Power Solutions for
availability.
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
MDC_OKX_T10T16-W5 Series.A06 Page 2 of 13
www.murata-ps.com/support
Performance and Functional Specifi cations
See Note 1
Input
Input Voltage Range See Ordering Guide and Note 7.
Start-Up Voltage 2.05V
Undervoltage Shutdown (see Note 15) 1.90V
Overvoltage Shutdown None
Refl ected (Back) Ripple Current (Note 2) 20 mA pk-pk
Internal Input Filter Type Capacitive
Recommended External Fuse 15A fast blow
Reverse Polarity Protection N/A. See fuse information
Input Current:
Full Load Conditions See Ordering Guide
Inrush Transient 0.4 A
2
Sec.
Shutdown Mode (Off, UV, OT) 5 mA
Output in Short Circuit 60 mA
No Load 80 mA
Low Line (Vin=Vmin, Vout=Vnom) 9.05A (T/10), 14.63A (T/16)
Remote On/Off Control (Note 5)
Negative Logic (“N” model suffi x) ON = Open pin or ground to +0.4V. max.
OFF =+1.5V min. to + Vin (max)
Positive Logic (“P” model suffi x) ON = Open pin (internally pulled up) or
+1.5V to +Vin max.
OFF = Ground pin to +0.4V. max.
Current 1 mA max.
Tracking/Sequencing (OKX “2” models)
Slew Rate 2 Volts per millisecond, max.
Tracking accuracy, rising input Vout = ±200 mV max. of Sequence In
Tracking accuracy, falling input Vout = ±400 mV max. of Sequence In
General and Safety
Effi ciency See Ordering Guide
Switching Frequency 300 KHz
Start-Up Time (Vin on to Vout regulated) 8 mSec for Vout=nominal
(On/Off to Vout regulated) 6 mSec for Vout=nominal
Isolation Not isolated
Safety Certifi ed to UL/cUL 60950-1,
CSA-C22.2 No. 60950-1, IEC/EN 60950-1
Calculated MTBF per Telcordia SR-232 (4a) TBC
Calculated MTBF per MIL-HDBK-217F (4b) TBC
Output
Minimum Loading No minimum load
Accuracy (50% load, untrimmed) ±2 % of Vnominal
Voltage Output Range (Note 13) See Ordering Guide
Overvoltage Protection (Note 16) None
Temperature Coeffi cient ±0.02% per °C of Vout range
Ripple/Noise (20 MHz bandwidth) See Ordering Guide and note 8
Line/Load Regulation See Ordering Guide and note 10
Maximum Capacitive Loading (Note 14)
Cap-ESR=0.001 to 0.01 Ohms 1,000 F
Cap-ESR >0.01 Ohms 5,000 F (min. cap. load 0
F
)
Current Limit Inception (Note 6) 34 Amps (OKX2-T/16-W5)
(98% of Vout setting, after warm up) 29 Amps (OKX2-T/10-W5)
Short Circuit Mode
Short Circuit Current Output 1 A
Protection Method Hiccup autorecovery upon overload
removal. (Note 7)
Short Circuit Duration Continuous, no damage
(output shorted to ground)
Prebias Startup Converter will start up if the external
output voltage is less than Vset
Dynamic Load Response 100 Sec max. to within ±2% of fi nal value
(50-100% load step, di/dt=2.5A/Sec) with
2 x 150
F polymer external caps.
Environmental
Operating Temperature Range (Ambient)
See derating curves -40 to +85 deg. C. with derating (Note 9)
Operating PC Board Temperature -40 to +100 deg. Celsius max.,
no derating (12)
Storage Temperature Range -55 to +125 deg. C.
Thermal Protection/Shutdown +130 deg. Celsius
Relative Humidity to 85%RH/+85 deg. C., non-condensing
Physical
Outline Dimensions See Mechanical Specifi cations
Weight 0.2 ounces (5.6 grams)
Restriction of Hazardous Substances RoHS-6
(does not claim EU RoHS
exemption 7b–lead in solder)
Absolute Maximum Ratings
Input Voltage (Continuous or transient) 0 V.to +5.8 Volts max.
On/Off Control 0 V. min. to +Vin max.
Input Reverse Polarity Protection See Fuse section
Output Current (Note 7) Current-limited. Devices can withstand a
sustained short circuit without damage.
The outputs are not intended to accept
appreciable reverse current.
Storage Temperature -55 to +125 deg. C.
Lead Temperature See soldering specifi cations
Absolute maximums are stress ratings. Exposure of devices to greater than any of any
of these conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifi cations Table is
not implied nor recommended.
Specifi cation Notes:
(1) Specifications are typical at +25 deg.C, Vin=nominal (+5V.), Vout=nominal (+3.3V), full load, external caps
and natural convection unless otherwise indicated. Extended tests at higher power must supply substantial
forced airflow.
All models are tested and specified with external 1 F paralleled with 10 F ceramic output capacitors
and a 22 F external input capacitor. All capacitors are low ESR types. These capacitors are necessary
to accommodate our test equipment and may not be required to achieve specified performance in your
applications. However, Murata Power Solutions recommends installation of these capacitors. All models are
stable and regulate within spec under no-load conditions.
(2) Input Back Ripple Current is tested and specified over a 5 Hz to 20 MHz bandwidth. Input filtering is
Cin=2 x 100 F tantalum, Cbus=1000 F electrolytic, Lbus=1 H.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. At higher
temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total
RMS current over time does not exceed the Derating curve.
(4a) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ISSUE 2,
ground fixed controlled conditions, Tambient=+25 deg.C, full output load, natural air convection.
(4b) Mean Time Before Failure is calculated using MIL-HDBK-217F, GB ground benign, Tambient=+25 deg.C, full
output load, natural air convection.
(5) The On/Off Control Input should use either a switch or an open collector/open drain transistor referenced to
-Input Common. A logic gate may also be used by applying appropriate external voltages which not exceed
+Vin.
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected
setting.
(7) “Hiccup” overcurrent operation repeatedly attempts to restart the converter with a brief, full-current output.
If the overcurrent condition still exists, the restart current will be removed and then tried again. This short
current pulse prevents overheating and damaging the converter. Once the fault is removed, the converter
immediately recovers normal operation.
(8) Output noise may be further reduced by adding an external filter. At zero output current, the output may
contain low frequency components which exceed the ripple specification. The output may be operated
indefinitely with no load.
OKX T/10 & T/16-W5 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
MDC_OKX_T10T16-W5 Series.A06 Page 3 of 13
www.murata-ps.com/support

OKX2-T/16-W5P-C

Mfr. #:
Manufacturer:
Description:
Non-Isolated DC/DC Converters 5Vin .75-3.6Vout 16A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union