PS60-103R-PMCN

MODEL NUMBER DESIGNATION
P S 6 0 - 1 0 2 R - N M C N
Series name
Signal / power cable pullout method
Pressure port
Switch output interface
Rated pressure range
Pressure reference
102100 ~ 100 kPa 103100 ~ 1000 kPa
302100 ~ 300 kPa
RCompound pressure (Negative pressure ~ Positive pressure)
CNConnector pullout
MM5 female screw
NNPN open collector
PPNP open collector
PRESSURE SWITCHES WITH GAUGE
PS60
Part name Material
Pressure port
“O” ring
Sensor module board
Housing
Display board
Operation panel seet
Polyamide (Resin of MXD6 series)
Brass (Ni-plated)
Fluoro-rubber
———
PBT (Polybutyleneterephtalate)
———
Polyester
INTERNAL STRUCTURE
OApplicable for negative through positive pressure with 10
mm thick slim housing
O
Suitable for use in clean rooms with easy-to-use push keys
O Plug-in connector is provided for easy installation and
maintenance
OSpace saving and mountable on DIN rails
OData protection by panel lock system
OLow consumption by nondisplay mode
FEATURES
LIST OF MODEL NUMBERS
Pressure port
M 5 female screw
NPN open collector output
PNP open collector output
Switch output
102R 302R 103R
100 ~ 100 kPa 100 ~ 300 kPa 100 ~ 1000 kPa
PS60-102R-NMCN PS60-302R-NMCN PS60-103R-NMCN
PS60-102R-PMCN PS60-302R-PMCN PS60-103R-PMCN
Verify the above model numbers when placing orders.
marking
Compatible with
EMC directive
1
2
3
4
6
5
1
2
3
4
5
6
PS60
PRESSURE SWITCHES WITH GAUGE
General specifications
Display Power
Item Model number
102R 302R 103R
PS60
STANDARD SPECIFICATIONS
Pressure reference Gauge
Non-corrosive gases
100 ~ 100 100 ~ 300 100 ~ 1000
200 600 1500
500 1000 2000
10 ~ 50
0 ~ 50
35 ~ 85
No condensation
20 ~ 70Atmospheric pressure, humidity 65 %RH maximum
Approx. 50
Includihg cable
12 ~ 24 V ± 10 %
Including ripple percentage
30
100 (500 V DC)
± 3 %F.S. (0 ~ 50 °C)
500 V AC, 60 s
Leakage current 1 mA maximum
M5 Female screw
3-digit LED
100 ~ 100 kPa 100 ~ 300 kPa 0.10 ~ 1.00 MPa
± 1 %F.S.
1 count
Pressure medium
Rated pressure range kPa
Maximum pressure kPa
Break-down pressure kPa
Operating temp. range °C
Compensated temp. range
°C
Operating humidity %RH
Storage temp. °C
Net weight g
Supply voltage V DC
Consumption current mA max.
Insulation resistance MΩ min.
Thermal error
Dielectric strength
Pressure port
Display element
Rated display range
Display accuracy
0 ∼ 50℃
Reference temp. 25 °C
Resolution
OUnless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
Switch output
0 ~ 30 counts
30 V 100 mA maximum
1.2 (NPN), 2.2 (PNP)
110 kPa (approx.) ~ “999” counts
Red LED ON
± 0.3 %F.S. maximum
Approx. 5, 25, 250
PS60 cable, DIN rail adaptor
Adjustable range
Switching capacity
Residual voltage V maximum
Display
Repeatability
Switch
hysteresis
Response ms
Accessories
Open collector output (NPN or PNP)
Adjustable by panel switch
2
No. of outputs
Output interface
Setting method
PS60
PRESSURE SWITCHES WITH GAUGE
CIRCUIT DIAGRAMS
Pressure
Load
S.Output1
Main circuit
Power B
Sensor
Common
S.Output2
Load
2
LED Indicator
1
LED
Pressure indication
Sensor
Main circuit
Pressure
Power B
S.Output2
1
LED Indicator
2
Pressure indication
LED
Common
S.Output1
Load Load
ONPN open collector OPNP open collector
SWITCH OUTPUT MODE
DISPLAY RANGE
Output
Mode
Operation
Pressure setting
(Operating point)
Setting 1 Setting 2
(Lower limit) : Setting 1
(Upper limit) : Setting 2
(Lower limit) : Setting 1
(Upper limit) : Setting 2
SW1 SW2
Separate mode Window comparator mode
S
-
1
S
-
2
S
-
3
S
-
4
C
-
5
C
-
6
C
-
7
C
-
8
Separate
Window comparator
Separate
Window comparator
HI LO A B HI LO A B
HI operation
LO operation
A operation
B operation
P1: SW1 P2: SW2 P1 P2
P1 P2
OFF
ON ON
ON
ON
-Pr
OFF OFF
OFF
Pr -Pr Pr
-Pr Pr
HH
P1: SW1
P2: SW2
OFF
ON
-Pr Pr
HH
HH
HH
H:Switch hysteresis
P1= Setting 1 、P 2 Setting 2
P1P2 or P1P2 P1P2–2H
Note 1. In the Separate Mode, setting 1 corresponds to SW1, and
Setting 2 corresponds to SW2.
Note 2. In the Window Comparator Mode, the minimum value for
SW1 and SW2 corresponds to Setting 1 and the maximum
value corresponds to Setting 2.
Atmospheric pressure
ODisplay range can be selected as the table.
Note) “–” on the table indicates that it is not selectable in relation to resolution and display lines.
: In terms of setting display range, please verify the default mode.
ENVIRONMENTAL CHARACTERISTICS
Test item Test conditions Permissible change
Vibration 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s
2
, 3 directions for 2 hours each
490 m/s
2
, 3 directions for 3 times each
40 °C, 90 ~ 95 %RH, 240 hrs.
0 ~ Rated pressure, 10
6
cycles
EMI : EN55011: 2007, A2 : 2007 Group 1, class Bý
EMS : EN61326-1 : 2006 Table 2
Pressure indication and switch operating output :
± 2 %F.S., maximum each after test
Pressure indication and switch operating output, alalog
output : ± 5 %F.S., maximum during test
Shock
Moisture resistance
Pressure cycling
EMC
Number
1 (kPa)
2 (MPa)
3
4
5
6
Rated pressure range
102R
–100 ~ 100 –100 ~ 300
–0.10 ~ 1.00
–75 ~ 75 –75 ~ 225
–1.00 ~ 1.00 –1.00 ~ 3.00 –1.0 ~ 10.0
–14.5 ~ 14.5 –14.5 ~ 43.5 –14 ~ 145
29.5 ~ 0.0
29.5 ~ 0.0
302R 103R

PS60-103R-PMCN

Mfr. #:
Manufacturer:
Description:
PRES SWITCH W/GAUGE NPN OPEN COL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet