ENC-120-48

Charger for lead-acid batteries (flooded, Gel and AGM)
and li-ion batteries (lithium iron and lithium manganese)
Built-in 3 stage programmable charging curve
Universal AC input / Full range
Built-in active PFC function
Fanless design, cooling by free air convection
Built-in temperature compensation function
Protection: Short circuit / Over voltage /Over temperature /
Battery under voltage / Battery over voltage / Battery reverse
polarity protection
3 years warranty
Radio system backup solution
Electric scooter charger
Surveillance system
Features Applications
Model Encoding
Description
Nominal voltage
Series name
ENC -- 120 24
ENC-120 is a single output 120W AC/DC desktop type charger with 3 stage charging curve. In addition to
the embedded pre-defined charging curves, the default curve is programmable and thus able to accommodate
different types of batteries, such as lead-acid batteries (gel, flooded and AGM) and li-ion batteries
(lithium iron and lithium manganese). With the rugged mechanical design along with the high efficiency
circuitry, ENC-120 operates for the ambient temperature range -30~+70 under free air convection.
Rated wattage
120W Programmable Desktop Type Battery Charger
ENC-120 series
File Name:ENC-120-SPEC 2018-05-07
UL60950-1 IEC60950-1
SPECIFICATION
120W Programmable Desktop Type Battery Charger
ENC-120 series
ENC-120-24 ENC-120-48ENC-120-12
MODEL
BOOST CHARGE VOLTAGE(Vboost)(default)
FLOAT CHARGE VOLTAGE(Vfloat)(default)
RATED POWER
OUTPUT CURRENT(CC) (default)
RECOMMENDED BATTERY
LEAKAGE CURRENT FROM
BATTERY (Typ.)
OUTPUT
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
REVERSE POLARITY
SAFETY STANDARDS
FUNCTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
TEMPERATURE COMPENSATION
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
SHORT CIRCUIT
Note.6
OVER VOLTAGE Note.7
PROTECTION
14.4V 28.8V 57.6V
13.8V 27.6V 55.2V
115.2W 115.2W 115.2W
8A
9 ~ 15V
4A
18 ~ 30V
2A
36 ~ 60V
30 ~ 80AH 15 ~ 40AH 10 ~ 20AH
<1mA
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC at full load
90% 90.5%89%
COLD START 65Aat 230VAC
<3.5mA / 240VAC
Protection type : Shut down O/P voltage, re-power on to recover
31 ~ 36.5V 62.1 ~ 72.9V
15.5 ~ 18.2V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
Shut down O/P voltage, recovers automatically after temperature goes down
By internal fuse
IEC60950-1, UL60950-1 EAC TP TC 004 approved
,
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-30 ~ +70 (Refer to "Derating Curve")
By NTC
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
206K hrs min. MIL-HDBK-217F (25 )
192*178*45.5mm (L*W*H)
0.98Kg; 10pcs/10.8Kg /1.38CUFT
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
3. This is the range when programming Vboost or Vfloat by using SBP-001, the smart battery charging programmer.
4. This is MEAN WELL's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
7. Each model incorporates a MCU-controlled dynamic over voltage protection, which is about 115% of Vboost over Constant Current stage and Constant
Voltage stage whereas 115% of Vfloat over Float stage.
8. The battery charger is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
1.25A/115VAC 0.63A/230VAC
AC CURRENT (Typ.)
CAPACITY (AMP HOURS)
Note.4
VOLTAGE RANGE Note.5
CHARGE VOLTAGE RANGE
Note.3
SAFETY &
EMC
(Note 8)
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Voltage Dips and Interruptions
Conducted
Radiated
Harmonic Current
Voltage Flicker
EN55024
Standard
Standard
EN55032 (CISPR32) / FCC PART15 (CISPR22)
EN55032 (CISPR32) / FCC PART15 (CISPR22)
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 4KV contact
Level 2, 3V/m
Level 2, 1KV
Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Class B
Class B
-----
-----
Level 2, 3Vrms
Level 1, 1A/m
File Name:ENC-120-SPEC 2018-05-07
File Name:ENC-120-SPEC 2018-05-07
Static CharacteristicsDerating Curve
Block Diagram
120W Programmable Desktop Type Battery Charger
ENC-120 series
DETECTION
PWM & PFC
CIRCUIT
O.L.P.
O.T.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
U.V.P.
&
O.C.P.
Charger mode select
Programable
MCU
PFC
CIRCUIT
ACTIVE START
CIRCUIT
PROTECTION
REVERSE
POLARITY
-30 0 2010 30 40
20
40
80
60
100
6050
70 (HORIZONTAL)
90 100 115 120 140 160 180 190 200 220 240 264
100
90
80
70
60
50
40
INPUT VOLTAGE (V) 60Hz
AMBIENT TEMPERATURE ( )
LOAD (%)
LOAD (%)

ENC-120-48

Mfr. #:
Manufacturer:
Description:
115.2W 57.6V 2A Desktop Single Output Battery Charge
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet