RACV12-24-LP

L-1
REV.: 0/2016www.recom-power.com
12 Watt
Constant
Voltage
Single
Output
AC/DC Converter
Features
LED
Driver
Low Profile Case (13mm height max.)
12V and 24V Constant Voltage Outputs
Terminal Block Input/Output with Cable Clamps
Fully Protected (OLP, SCP, OCP, OTP)
low Standby Power, ErP conform
low cost
RACV12-LP
Description
These low profile constant voltage LED drivers have been designed for cost-sensitive applications.
The SELV outputs are suitable for both independently supplied or built-in power-supply LED luminaires.
Their low profile design allows them to be invisibly built into furniture, discreetly mounted under shelves
or integrated in space-restricted applications such as coving lighting, strip lighting or troffer lighting sys-
tems. The power supplies are short circuit and overload protected and come with a full 3-year warranty.
Selection Guide
Part nom. Input Input Output Output Efficiency Output
Number Voltage Current Voltage Current Range typ. Power max.
[VAC] [mA] [VDC] [mA] [%] [W]
RACV12-12-LP 230 130 12 0-1000 78 12W
RACV12-24-LP 230 130 24 0-500 80 12W
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range 198VAC 230VAC 264VAC
Inrush Current 8A
Start-up Time 50ms
Input Frequency Range 47Hz 63Hz
No Load Power Consumption 0.4W
Power Factor full load, 230VAC 0.55
Internal Operating Frequency full load 35kHz 140kHz
Output Ripple Voltage
(1)
12Vout
24Vout
600mVp-p
500mVp-p
Specifications (measured @ ta= 25°C, 240VAC and rated load)
All LED Drivers may not be used without a load. They must be switched on the primary side only.
Noncompliance may damage the LED or reduce its lifetime.
REGULATIONS
Parameter Condition Value
Output Voltage Accuracy ±5% max.
Line Regulation 3% max.
Load Regulation 3% max.
Notes:
Note1: Measured at 20MHz BW using 0.1µF & 47µF parallel capacitor.
ERP
compliant
IEC/EN61347-1 Certified
IEC/EN61347-2-13 Certified
ENEC Certified
CB Report
EN55015 Compliant
PROTECTION
Parameter Condition Value
Input Fuse external fuse is recommended T1A
Open Circuit Protection (OCP)
auto recovery after fault condition is removed
Over Load Protection (OLP)
auto recovery after fault condition is removed
Over Voltage Protection (OVP)
auto recovery after fault condition is removed
Over Temperature Protection (OTP) 110°C Tcase
auto recovery after fault condition is removed
Isolation Voltage I/P to O/P 3.75kVAC / 1 minute
AC/DC Converter
L-2
REV.: 0/2016 www.recom-power.com
Specifications (measured @ ta= 25°C, 240VAC and rated load)
RACV12-LP
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range -20°C to +50°C, Ambient
Maximum Case Temperature +85°C
Operating Altitude 2000m
Operating Humidity 5% to 85% RH, non condensing
IP Rating IP20
Pollution Degree PD2
Design Lifetime 30 x 10³ hours
Derating Graph
-20 6050403020100-10
0
20
40
60
80
100
Ambient Temperature [°C]
Output Current [%]
Maximum loading of automatic circuit breakers
@ 230VAC, 1Ohm, 90° phase angle and max. load
Circuit Breaker Circuit Breaker Current
Typ 10A 16A 20A 25A
B 17 28 35 44
C 37 59 74 92
SAFETY AND CERTIFICATIONS
Certificate Type Report Number Standard
Lamp Controlgear General Requirments for Safety
305987
+
305985
IEC61347-1, 2nd Edition, 2012
EN61347-1, 2nd Edition 2013
Lamp Controlgear Particular Requirements
IEC61347-2-13, 2nd Edition, 2014
EN61347-2-13, 2014
D.C. or A.C. Controlgears for LED Performance Requirements 305984-1 + 305984-1 IEC/EN62384, 1st Edition, 2009
RoHS 2.1 LCS1606201548R RoHS-2011/65/EU + AM-2015/863
continued on next page
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material Case Plastic (UL94V-2)
Package Dimension (LxWxH) 128.0 x 50.0 x 13.0mm
Package Weight 70g
AC/DC Converter
L-3
REV.: 0/2016www.recom-power.com
RACV12-LP
Series
Specifications (measured @ ta= 25°C, 240VAC and rated load)
50.0
50.0
FC 44.0
13.0
2.0
18.0
52.0
128.0
FC 115.0
tc
PRI
2
1
SEC
3
4
M3 Screws
Mechanical Dimensions
2 mounting screws are included
wire preparation
6-7mm
EMI Compliance Standard / Criterion
Equipment for general Lighting Purpose - EMC Immunity Requirements
305984
+
305985
EN61547, 2009
Limits and methods of measurement of radio disturbance characteristics of electrical
lighting and similar equipment
EN55015, 2015
Assessment of lighting equipment related to human exposure to electromagnetic fields
EN61493, 2015
ESD Electrostatic discharge immunity test
±8kV Air Discharge,
±4kV Contact Discharge
EN61000-4-2, 2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test 3V/m
EN61000-4-3, 2010, Criteria A
Fast Transient and Burst Immunity
±0.5kV (DC Output)
±1kV (AC Input)
EN61000-4-4, 2012, Criteria B
Surge Immunity ±0.5kV (AC Input) EN61000-4-5, 2014, Criteria C
Immunity to conducted disturbances, induced by radio-frequency fields 3V EN61000-4-6, 2014, Criteria A
Voltage Dips and Interuptions
95% reduction
30% reduction
EN61000-4-11, 2014, Criteria B
EN61000-4-11, 2014, Criteria C
Limits of Harmonic Current Emissions
EN61000-3-2, Class C, 2014
Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase
EN61000-3-3, 2013
Connection via Screw Terminal
# Function Solid Wire Stranded Wire
(2)
AWG
1 VAC in (N) 0.75-1.5mm² 0.75-1.5mm² 20-16
2 VAC in (L) 0.75-1.5mm² 0.75-1.5mm² 20-16
3 LED+ 0.5-1.5mm² 0.5-1.5mm² 21-16
4 LED- 0.5-1.5mm² 0.5-1.5mm² 21-16
wire stripping length: 6-7mm
recommended tightening torque: 0.25Nm
tc= case temperature measuring point
FC = fixing centers
NC= no connection
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
Notes:
Note2: The use of sleeve or ferrule terminations is recommended.

RACV12-24-LP

Mfr. #:
Manufacturer:
RECOM Power
Description:
LED Power Supplies 12W 230Vin 24Vout 0-500mA
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet