Applications
Time delay in turning off the auxiliary winding
of single-phase AC motors
Features
Metallization: CrNi (sputtered) + Ag
(screen-printed)
Excellent long-term reliability
Suitable for clamp contacting
For approvals see table below
RoHS-compatible
Delivery mode
Bulk
Dimensional drawing
General technical data
Switching cycles N > 100000
Operating temperature range (V = 0) T
op
+5/+80 °C
Operating temperature range (V = V
max
) T
op
+5/+80 °C
Electrical specifications and ordering codes
Type
I
max
A
V
max
V
T
ref
(typ.)
°C
t
S
1)
s
V
BD
2)
V
R
R
±∆R
R
(V
PTC
≤ 2.5 V)
Ω
Ordering code
1) Measured at V = V
max
and I = 0.8 I
max
2) PTC clamped between crown contacts (diameter: 2 mm).
V
R
= 120 V
RMS
A546 12 180 135 0.45 > 360 4.70 ±20% B59546A0135A020
A548 12 200 135 0.30 > 400 6.80 ±20% B59548A0135A020
V
R
= 230 V
RMS
A551 5 400 135 0.25 > 710 47 ±20% B59551A0135A020
A549 8 350 135 0.30 > 640 22 ±20% B59549A0135A020
A550 8 355 135 0.25 > 700 33 ±20% B59550A0135A020
A556 8 350 135 0.35 > 600 15 ±20% B59556A0135A020
Motor starting
Low power consumption
Page 2 of 9Please read Cautions and warnings and
Important notes at the end of this document.