LB130S
130W Single Output LED Supply
www.slpower.com LB130S56K REV 1.9 15-APRIL-14
Output Power
Maximum of 130 Watts conduction at
70°C
200 Watts of peak for minimum of 60
Sec @ 50°C
Switching
Frequency
PFC: Fixed, 65kHz
Main Converter: Variable 35-200kHz, 65-
70kHz at full load
Transient
Response
500µS typical, return to 0.5% of nominal,
∆i/∆t: <0.2A/µS. Max Voltage Deviation
= 3%
Test Conditions:
a)5% to 50% load change
b)50% to 100% load change
c)100% to 50%
d)50% to 5%
Isolation
Input-Output: 3,000Vac
Input-Ground: 1,800Vac
Output-Ground: 1,500Vac
Ripple and
Noise
0.5%rms, 1% pk-pk, see chart.
Operating
Temperature
: -10°C to +70°C Full
Load
Convection Cooled: -10°C to +50°C Full
Load, 110 Watts @ 60°C, 90 Watts @70C
Start Up at -40°C
Output Voltage
56V
Heat-Sink
Temperature
To maintain Safety approval & life
expectancy, heat-sink temperature should
not exceed 85°C
Voltage
Adjustability
Fixed Output
Storage
Temperature
-40°C to +85°C
Minimum Load
Not required
Altitude
Operating: -457 to 3000 m
Non-operating: -457 to 12,192m.
Total Regulation
+/- 3% combined line, load and initial
setting.
Relative
Humidity
5% to 95%, non-condensing
Vibration
Operating: 0.003g²/Hz, 1.5grms overall,
3 axes, 10 min/axis
Non-Operating: 0.026g²/Hz, 5.0grms
overall, 3 axes, 1 hr/axis
Shock
Operating: Half-sine, 20gpk, 10ms, 3 axes,
6 shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms,
3axes, 6 shocks total
Dimensions
W: 3.0” x L: 5.0” x H: 1.3”
Safety
Standards
EN/CSA/UL/IEC 60950-1, 2nd Edition
Weight
380g
Life
50,000 Hrs at 70°C, 130 Watts of output,
115Vac or 230Vac input Voltage
The specification above is based on 25°C ambient
.