MLX90251
Programmable Linear Hall Effect Sensor
3901090251 Page 4 of 20 Data Sheet
Rev 012 Oct/2012
3 Glossary of Terms
Term Explanation
mT (milli-Tesla) Unit of measurement for magnetic flux density. 1mT is equal to 10 Gauss.
V
OQ
(Output Quiescent
Voltage)
Output voltage at zero magnetic field, V
OUT
for B = 0 mT.
Sensitivity Change in output voltage versus change in magnetic field ( V
OUT
/ B)
TempCo (Sensitivity
Temperature Compensation)
Change in Sensitivity over temperature.
Listed in units of ppm / °C (where 100ppm / °C. = 0.01% / °C)
PTC (Programming Through
the Connector)
Melexis in-circuit programming protocol.
MSB Most Significant Bit.
LSB Least Significant Bit.
4 Maximum Ratings
Parameter Units
Maximum Supply Voltage, V
DD_MAX
(over
Voltage)
30 V
Maximum Supply Current, I
DD_MAX
(Over Voltage)
50 mA
Reverse Voltage, V
DD_REV
- 15 V
Reverse Supply Current, I
DD_REV
- 85 mA
Positive Output Voltage, V
OUT_MAX
24 V
Positive Output Current, I
OUT_POS_FAULT
40 mA
Reverse Output Voltage, V
OUT_REV
- 0.7 V
Reverse Output Current, I
OUT_REV_FAULT
-50 mA
Operating Ambient Temperature Range, T
A
-40°C to 150°C
Storage Temperature Range, T
S
-55°C to 165°C
Magnetic Flux Density Infinite
Table 2: Absolute Maximum Ratings
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
MLX90251
Programmable Linear Hall Effect Sensor
3901090251 Page 5 of 20 Data Sheet
Rev 012 Oct/2012
5 Detailed Block Diagram
Figure 5-1 Detailed Block Diagram
5.1 Detailed Description
Integrated on the MLX90251 is a temperature-compensated quad switched Hall plate, chopper stabilized
amplifiers, adjustable output filter, output driver, voltage protection circuitry and a programmable EEPROM
with security and redundancy. Programming the EEPROM allows each device to be calibrated in the
application.
In normal operation data stored in the EEPROM feeds a register, RAM, that updates internal DACs and
switches that effect the operation of the device. In programming mode the RAM can be directly accessed to
allow faster calibration of the parameters. Communication to the device is done using Melexis' PTC serial
interface.
MLX90251
Programmable Linear Hall Effect Sensor
3901090251 Page 6 of 20 Data Sheet
Rev 012 Oct/2012
6 General Electrical Specifications
DC operating parameters at V
DD
= 5V (unless otherwise specified) and for T
A
as specified by the temperature
range (E or L).
Parameter Symbol Test Conditions Min Typical
Max Units
Nominal Supply Voltage V
DDNOM
- 5 - V
Operating Supply Voltage V
DD
4.5 - 5.5 V
Nominal Supply Current I
DDNOM
V
DD
= V
DDNOM
4.0 7.0 8.0 mA
Supply Current I
DD
V
DD
= 4.5 … 5.5 V 3.0 - 9.0 mA
Output Voltage Swing
V
OUTPD
Pull Down Load ≥ 10 kΩ
no clamping
2 96 %V
DD
V
OUTPU
Pull Up Load ≥ 10 kΩ
no clamping
5 97 %V
DD
Output Current I
OUT
V
DD
= V
DDNOM
-1.25 1.25 mA
Output Short-Circuit Current
I
OUTSC+
I
OUTSC-
V
DD
= V
DDNOM
Output shorted to supply-permanent
Output shorted to ground-permanent
-12
4
-4
12
mA
mA
Diagnostic Output Voltage
V
OUT1
Broken supply,
Pull-down load > 10 kΩ
0 0.5
%V
DD
%V
DD
%V
DD
%V
DD
V
OUT2
Broken ground,
Pull-down load > 10 kΩ
94 96 100
V
OUT3
Broken supply,
Pull-up load > 10 kΩ
0 3 5
V
OUT4
Broken ground,
Pull-up load > 10 kΩ
99.5 100
Power on Reset V
DD_POR
Voltage on V
DD
1.5 3.8 V
Over Voltage Detection V
DD_OVD
Voltage on V
DD
6.5 8.5 V
Table 3: Electrical Specifications
The ratiometric output voltage is proportional to the supply voltage. When using the supply voltage as a
reference for an A/D converter, fluctuations of ±10% in supply voltage are compensated.

MLX90251EVA-FAA-200-SP

Mfr. #:
Manufacturer:
Melexis
Description:
Board Mount Hall Effect / Magnetic Sensors Programmable Linear Hall ICs (Gen. II)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union