MLX90251
Programmable Linear Hall Effect Sensor
3901090251 Page 4 of 20 Data Sheet
Rev 012 Oct/2012
3 Glossary of Terms
Term Explanation
mT (milli-Tesla) Unit of measurement for magnetic flux density. 1mT is equal to 10 Gauss.
V
OQ
(Output Quiescent
Voltage)
Output voltage at zero magnetic field, V
OUT
for B = 0 mT.
Sensitivity Change in output voltage versus change in magnetic field (∆ V
/ ∆ B)
TempCo (Sensitivity
Temperature Compensation)
Change in Sensitivity over temperature.
Listed in units of ppm / °C (where 100ppm / °C. = 0.01% / °C)
PTC (Programming Through
the Connector)
Melexis in-circuit programming protocol.
MSB Most Significant Bit.
LSB Least Significant Bit.
4 Maximum Ratings
Parameter Units
Maximum Supply Voltage, V
DD_MAX
(over
Voltage)
30 V
Maximum Supply Current, I
DD_MAX
(Over Voltage)
50 mA
Reverse Voltage, V
DD_REV
- 15 V
Reverse Supply Current, I
DD_REV
- 85 mA
Positive Output Voltage, V
OUT_MAX
24 V
Positive Output Current, I
OUT_POS_FAULT
40 mA
Reverse Output Voltage, V
OUT_REV
- 0.7 V
Reverse Output Current, I
OUT_REV_FAULT
-50 mA
Operating Ambient Temperature Range, T
A
-40°C to 150°C
Storage Temperature Range, T
S
-55°C to 165°C
Magnetic Flux Density Infinite
Table 2: Absolute Maximum Ratings
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-