DESIGN OBJECTIVES 07 Mar 11
DESIGN OBJECTIVES
108-36033
Test Description Requirem ent Procedure
Barom etric pressure, tem perature
cycling.
See Note. MIL-STD 202, Method 105C,
Condition C.
Herm etic seal. Leakage rate less than 1 X 10 cc
-8
He/sec.
See Note.
MIL-STD 202, Method 112C,
Condition C.
Shall meet visual requirements, show no physical damage, and meet requirements of additional
NOTE
tests as specified in the Product Qualification and Requalification Test Sequence shown in Figure
2.
Figure 1 (end)
3.6. Product Qualification and Requalification Test Sequence
Test or Exam ination
Test Group (a)
1 2(c)
Test Sequence (b)
Initial exam ination of product 1,19 1,18
Contact resistance 4,8 5,9
Insulation resistance 2 3
W ithstanding voltage 3,11,15 4,13,17
Vibration 9 10
Mechanical shock 10 11
Durability 7 8
Contact engaging force 5,17 6
Contact separating force 6,18 7
Thermal shock 14 15
Humidity, steady state 12 14
Tem perature life 16
Barom etric pressure, tem perature cycling 13(d)
Hermetic seal 2,12,16
Final exam ination of product 19 18
(a) See paragraph 4.1.A.
NOTE
(b) Numbers indicate sequence in which tests are performed.
(c) This test group is applicable to hermetic seal type receptacles only.
(d) HiPot is performed at each temperature extreme and reduced barometric pressure,
70000 feet.
Figure 2
Rev O2 4 of 6