HL2-L-AC120V-F

–1–
ASCTB114E 201709-T
ORDERING INFORMATION
Relay for control panel of
1c 15A, and 2c 10A
HL RELAYS
RoHS compliant
FEATURES
1. Compact high-capacity control relay
In the same external dimensions as an
HC relay, this compact power relay
enables high-capacity control:
15 A for 1 Form C, 10 A for 2 Form C.
2. Designed for high reliability
High operational reliability is achieved by
solder-less construction, in which all
connections between lead wires and the
contact springs and terminal plate are
welded.
3. Various types provided in rich
lineup. LED indicator and diode type
is also available.
4. The terminals are compatible with
#187 series tab terminals.
5. Sockets and terminal sockets are
available.
TYPICAL APPLICATIONS
1. Factory automation equipment and
automotive devices
2. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
3. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
4. All types of household appliance
Contact arrangement
1: 1 Form C
2: 2 Form C
HL F
Surge absorber
*D: with diode
Contact material
F: AgSnO2 type
Terminal arrangement
H:
L:
HP:
PL:
HTM:
Plug-in type
Plug-in type with LED indication
PC board type
PC board type with LED indication
TM type
Nominal coil voltage
AC
DC
6, 12, 24, 48, 100 (100/110), 120 (110/120),
200 (200/220), 240 (220/240) V
6, 12, 24, 48, 100 (100/110) V
Notes: 1. Certified by C-UL, CSA and TÜV
Please inquire about TV approved products.
2. *Diode type is available. (DC coil Plug-in type with LED indication only)
3. The LED indication color is green for the DC coil and red for the AC coil.
       
To Be Discontinued
Last time buy: September 30, 2018
HL
–2–
ASCTB114E 201709-T
TYPES
1. Plug-in type
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
2. Plug-in type (with LED indication)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Nominal coil
voltage
1 Form C 2 Form C
Part No. Part No.
6V AC HL1-H-AC6V-F HL2-H-AC6V-F
12V AC HL1-H-AC12V-F HL2-H-AC12V-F
24V AC HL1-H-AC24V-F HL2-H-AC24V-F
48V AC HL1-H-AC48V-F HL2-H-AC48V-F
100/110V AC HL1-H-AC100V-F HL2-H-AC100V-F
110/120V AC HL1-H-AC120V-F HL2-H-AC120V-F
200/220V AC HL1-H-AC200V-F HL2-H-AC200V-F
220/240V AC HL1-H-AC240V-F HL2-H-AC240V-F
6V DC HL1-H-DC6V-F HL2-H-DC6V-F
12V DC HL1-H-DC12V-F HL2-H-DC12V-F
24V DC HL1-H-DC24V-F HL2-H-DC24V-F
48V DC HL1-H-DC48V-F HL2-H-DC48V-F
100/110V DC HL1-H-DC100V-F HL2-H-DC100V-F
Nominal coil
voltage
1 Form C 2 Form C
Part No. Part No.
6V AC HL1-L-AC6V-F HL2-L-AC6V-F
12V AC HL1-L-AC12V-F HL2-L-AC12V-F
24V AC HL1-L-AC24V-F HL2-L-AC24V-F
48V AC HL1-L-AC48V-F HL2-L-AC48V-F
100/110V AC HL1-L-AC100V-F HL2-L-AC100V-F
110/120V AC HL1-L-AC120V-F HL2-L-AC120V-F
200/220V AC HL1-L-AC200V-F HL2-L-AC200V-F
220/240V AC HL1-L-AC240V-F HL2-L-AC240V-F
6V DC HL1-L-DC6V-F HL2-L-DC6V-F
12V DC HL1-L-DC12V-F HL2-L-DC12V-F
24V DC HL1-L-DC24V-F HL2-L-DC24V-F
48V DC HL1-L-DC48V-F HL2-L-DC48V-F
100/110V DC HL1-L-DC100V-F HL2-L-DC100V-F
3. Plug-in type (with LED indication and diode)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
4. PC board type
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Nominal coil
voltage
1 Form C 2 Form C
Part No. Part No.
6V DC HL1-L-DC6V-D-F HL2-L-DC6V-D-F
12V DC HL1-L-DC12V-D-F HL2-L-DC12V-D-F
24V DC HL1-L-DC24V-D-F HL2-L-DC24V-D-F
48V DC HL1-L-DC48V-D-F HL2-L-DC48V-D-F
100/110V DC HL1-L-DC100V-D-F HL2-L-DC100V-D-F
Nominal coil
voltage
1 Form C 2 Form C
Part No. Part No.
6V AC HL1-HP-AC6V-F HL2-HP-AC6V-F
12V AC HL1-HP-AC12V-F HL2-HP-AC12V-F
24V AC HL1-HP-AC24V-F HL2-HP-AC24V-F
48V AC HL1-HP-AC48V-F HL2-HP-AC48V-F
100/110V AC HL1-HP-AC100V-F HL2-HP-AC100V-F
110/120V AC HL1-HP-AC120V-F HL2-HP-AC120V-F
200/220V AC HL1-HP-AC200V-F HL2-HP-AC200V-F
220/240V AC HL1-HP-AC240V-F HL2-HP-AC240V-F
6V DC HL1-HP-DC6V-F HL2-HP-DC6V-F
12V DC HL1-HP-DC12V-F HL2-HP-DC12V-F
24V DC HL1-HP-DC24V-F HL2-HP-DC24V-F
48V DC HL1-HP-DC48V-F HL2-HP-DC48V-F
100/110V DC HL1-HP-DC100V-F HL2-HP-DC100V-F
5. PC board type (with LED indication)
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
6. TM type
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
Nominal coil
voltage
1 Form C 2 Form C
Part No. Part No.
6V AC HL1-PL-AC6V-F HL2-PL-AC6V-F
12V AC HL1-PL-AC12V-F HL2-PL-AC12V-F
24V AC HL1-PL-AC24V-F HL2-PL-AC24V-F
48V AC HL1-PL-AC48V-F HL2-PL-AC48V-F
100/110V AC HL1-PL-AC100V-F HL2-PL-AC100V-F
110/120V AC HL1-PL-AC120V-F HL2-PL-AC120V-F
200/220V AC HL1-PL-AC200V-F HL2-PL-AC200V-F
220/240V AC HL1-PL-AC240V-F HL2-PL-AC240V-F
6V DC HL1-PL-DC6V-F HL2-PL-DC6V-F
12V DC HL1-PL-DC12V-F HL2-PL-DC12V-F
24V DC HL1-PL-DC24V-F HL2-PL-DC24V-F
48V DC HL1-PL-DC48V-F HL2-PL-DC48V-F
100/110V DC HL1-PL-DC100V-F HL2-PL-DC100V-F
Nominal coil
voltage
1 Form C 2 Form C
Part No. Part No.
6V AC HL1-HTM-AC6V-F HL2-HTM-AC6V-F
12V AC HL1-HTM-AC12V-F HL2-HTM-AC12V-F
24V AC HL1-HTM-AC24V-F HL2-HTM-AC24V-F
48V AC HL1-HTM-AC48V-F HL2-HTM-AC48V-F
100/110V AC HL1-HTM-AC100V-F HL2-HTM-AC100V-F
110/120V AC HL1-HTM-AC120V-F HL2-HTM-AC120V-F
200/220V AC HL1-HTM-AC200V-F HL2-HTM-AC200V-F
220/240V AC HL1-HTM-AC240V-F HL2-HTM-AC240V-F
6V DC HL1-HTM-DC6V-F HL2-HTM-DC6V-F
12V DC HL1-HTM-DC12V-F HL2-HTM-DC12V-F
24V DC HL1-HTM-DC24V-F HL2-HTM-DC24V-F
48V DC HL1-HTM-DC48V-F HL2-HTM-DC48V-F
100/110V DC HL1-HTM-DC100V-F HL2-HTM-DC100V-F
       
To Be Discontinued
Last time buy: September 30, 2018
HL
–3–
ASCTB114E 201709-T
RATING
1. Coil data
1) AC coils
Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading
possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20
°
C 68
°
F)
Notes: 1. The nominal operating current is
±
10% (20
°
C 68
°
F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20
°
C 68
°
F. Compensate
±
0.4% for every
±
1
°
C change in temperature.
3. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
nominal voltage.
4. For use with 200 V DC, connect a 10 K
Ω
(5W) resistor, in series, to the 100 V DC relay.
5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50
°
C to +40
°
C –58
°
F to +104
°
F (AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket, be sure to verify the max. continuous current.
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating power
(VA)
Pick-up voltage
(at 20
°
C 68
°
F)
Drop-out voltage
(at 20
°
C 68
°
F)
Inductance (H)
Max. applied
voltage
(at 70
°
C 158
°
F)
50Hz 60Hz 50Hz 60Hz When drop-out When operating
6V AC 224 200
1.3 1.2
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
0.078 0.074
110%V of
nominal voltage
12V AC 111 100 0.312 0.295
24V AC 56 50 1.243 1.181
48V AC 28 25 4.974 4.145
100/110V AC 13.4/14.7 12/13.2 23.75 20.63
110/120V AC 12.2/13.5 10.9/11.9 27.19 25.57
200/220V AC 6.7/7.4 6/6.6 85.98 81.76
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating
power (W)
Coil resistance
(
Ω
)
Pick-up voltage
(at 20
°
C 68
°
F)
Drop-out voltage
(at 20
°
C 68
°
F)
Max. applied voltage
(at 70
°
C 158
°
F)
6V DC 150
0.9
40
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V DC 75 160
24V DC 37 650
48V DC 18.5 2,600
100/110V DC 10 1.0 10,000
Characteristics Item Specifications
Contact
Contact resistance (Initial) Max. 50 m
Ω
(By voltage drop 6 V DC 1A)
Contact material AgSnO
2
type
Rating
Nominal switching capacity*
4
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 250V AC (resistive load)
Min. switching capacity (Reference value)*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100M
Ω
(at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact sets 1,500 Vrms for 1min. (Detection current: 10mA)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA)
Temperature rise (coil) Max. 80
°
C 176
°
F (By resistive method, nominal voltage)
Operate time (at 20
°
C 68
°
F)*
2
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time (at 20
°
C 68
°
F)*
2
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 196 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10
μ
s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10
μ
s.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life
Mechanical AC type: 5
×
10
7
(at 180 times/min.), DC type: 10
8
(at 180 times/min.)
Electrical
AC load
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cos
ϕ
=1) Life switching cycle: Min. 5
×
10
5
2 Form C: 10A 250V AC resistive load (cos
ϕ
=1) Life switching cycle: Min. 3
×
10
5
DC load
1 Form C: 3A 30V DC resistive load (cos
ϕ
=1) Life switching cycle: Min. 5
×
10
5
2 Form C: 3A 30V DC resistive load (cos
ϕ
=1) Life switching cycle: Min. 5
×
10
5
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –50
°
C to +70
°
C –58
°
F to +158
°
F (Without LED indication);
–50
°
C to +60
°
C –58
°
F to +140
°
F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. Operating speed 20 times/min. (at max. rating)
Unit weight Approx. 35g 1.23 oz
       
To Be Discontinued
Last time buy: September 30, 2018

HL2-L-AC120V-F

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
General Purpose Relays HL2 Relay (Plug-in w/ LED, Cd-Free)
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union