PD30CNB15NPRT

4 Specifications are subject to change without notice (14.06.2016)
Normal operation, optimized switching point.
1. Line up the sensor at the background. Yellow LED is
not important and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Place the object in the detection zone.
4. Press the button once and the sensor is ready to
operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
a) if the object is to close to the background the
sensor will teach both background and object as
object.
For maximum sensing distance
(default setting)
1. Line up the sensor without a background. Yellow LED
is not important and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
For minimum sensing distance
1. Line up the sensor at the object. Yellow LED is not
important and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate(Green LED ON, Yellow LED ON)
(The second switch point is stored)
For dynamic set-up (running process)
1. Line up the sensor at the object. Green LED is ON,
status on the yellow LED is not important.
2. Press the button for 3 second until both LEDs
flashes simultaneously.
3. Press the button a second time for at least one
second, both LED’s flashes fast siultainiously and
keep the button pressed for at least one process
cycle, release the button and the sensor is ready
to operate (The second switch point is stored)
For make or break set-up (N.O. or N.C.)
1. Press the button for 10 seconds, until the green
LEDs flashes.
2. While the green LED flashes, the output is inverted
each time the button is pressed. Yellow LED indi-
cates N.O. function selected.
If the button is not pressed within the next 10
seconds, the current output is stored.
Teach functions
PD30CNB15....RT
12 4
3 sec. Push once
3
12
3 sec. Push once
3
12
3 sec. Push once
3
12 3
3 sec. One cycle
10 sec.
12
Push once

PD30CNB15NPRT

Mfr. #:
Manufacturer:
Description:
SENSOR REFLECTIVE 150MM NPN
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union