Data Sheet
October 1, 2009
Austin Lynx
TM
SIP Non-Isolated dc-dc Power Modules:
3.0 Vdc - 5.5 Vdc Input, 0.9 Vdc - 3.3 Vdc Output, 10 A
Document Name: FDS02-047EPS ver.1.6
PDF Name: Austin Lynx SIP
Applications
n
Distributed Power Architectures
n
Wireless Networks
n
Access and Optical Network Equipment
n
Enterprise Networks
n
Data processing Equipment
n
Latest generation IC’s (DSP, FPGA, ASIC) and Micropro-
cessor-powered applications.
Options
n
Remote Sense
n
Long Pins: 5.08 mm ± 0.25 mm
(0.200 in ± 0.010 in)
Features
n
Compatible with RoHS EU Directive 200295/EC (-Z Ver-
sions)
n
Compatible in RoHS EU Directive 200295/EC with lead
solder exemption (non -Z versions)
n
Delivers up to 10A output current
n
High efficiency: 95% at 3.3V full load
n
Small size and low profile:
50.8 mm x 8.10mm x 12.7mm
(2.0 in x 0.32 in x 0.5 in)
n
Light Weight 0.27 oz(7.5 g)
n
Cost-efficient open frame design
n
High reliability: MTBF > 10M hours at 25 °C
n
Remote On/Off
n
Output overcurrent protection with auto-restart
n
Overtemperature protection
n
Constant frequency (300 kHz,typical)
n
Adjustable output voltage ± 10% of VO (–5% to + 10% for
0.9 V output)
n
Single-In-Line (SIP) Package
n
UL* 60950 Recognized, CSA
C22.2 No. 60950-00 Certi-
fied, and VDE
0805 (IEC60950, 3rd edition) Licensed
RoHS Compliant
Description
Austin Lynx™ power modules are non-isolated dc-dc converters that can deliver 10 A of output current with full load efficiency of
95% at 3.3 V output. These open frame modules in SIP package enable designers to develop cost-and space efficient solutions.
Standard features include remote ON/OFF, output voltage adjustment, overcurrent and overtemperature protection.
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
§ This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. (The CE mark is placed on selected products.)
** ISO is a registered trademark of the Internation Organization of Standards
Lineage Power 2
Data Sheet
October 1, 2009
3.0 Vdc - 5.5 Vdc Input, 0.9 Vdc - 3.3 Vdc Output, 10 A
Austin Lynx
TM
SIP Non-Isolated dc-dc Power Modules:
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the
operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the
device reliabiltiy.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
To preserve maximum flexibility, internal fusing is not included; however, to achieve maximum safety and
system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 20A.
Parameter Device Symbol Min Max Unit
Input Voltage:
Continuous All VIN 0 6.5 Vdc
Operating Ambient Temperature All TA –40 85 °C
Storage Temperature All Tstg –55 125 °C
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage AXH010A0S0R9
AXH010A0S1R0
AXH010A0P
AXH010A0M
AXH010A0Y
AXH010A0D
AXH010A0G
AXH010A0F
VIN
VIN
VIN
VIN
VIN
VIN
VIN
VIN
3.0
3.0
3.0
3.0
3.0
3.0
3.0
4.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Maximum Input Current
(VI = 0 to VI,max; IO = IO,max)
II,max 9.5 A
Input Reflected-Ripple Current
(5 Hz to 20 MHz; 1 µH source impedance; TA = 25
°C; CIN = 200 µF)
30 mAp-p
Input Ripple Rejection
(100 - 120Hz)
40 dB
Lineage Power 3
Data Sheet
October 1, 2009
3.0 Vdc - 5.5 Vdc Input, 0.9 Vdc - 3.3 Vdc Output, 10 A
Austin Lynx
TM
SIP Non-Isolated dc-dc Power Modules:
Electrical Specifications (continued)
General Specifications
Parameter Device Symbol Min Typ Max Unit
Output Voltage Set Point
(VI = 5V; IO = IO,max; TA = 25 °C)
AXH010A0S0R9
AXH010A0S1R0
AXH010A0P
AXH010A0M
AXH010A0Y
AXH010A0D
AXH010A0G
AXH010A0F
VO,set
VO,set
VO,set
VO,set
VO,set
VO,set
VO,set
VO,set
0.886
0.985
1.182
1.47
1.764
1.97
2.45
3.234
0.9
1.0
1.2
1.5
1.8
2.0
2.5
3.3
0.914
1.015
1.218
1.53
1.836
2.03
2.55
3.366
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions at steady state until end of life.)
AXH010A0S0R9
AXH010A0S1R0
AXH010A0P
AXH010A0M
AXH010A0Y
AXH010A0D
AXH010A0G
AXH010A0F
VO
VO
VO
VO
VO
VO
VO
VO
0.873
0.970
1.164
1.455
1.746
1.94
2.425
3.2
0.927
1.03
1.236
1.545
1.854
2.06
2.575
3.4
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Output Regulation:
Line (VI = VI, min to VI, max)
Load (IO = IO, min to IO, max)
Temperature (TA = TA, min to TA, max)
All
All
All
0.2
0.4
0.5
%VO
, s
et
%VO, set
%VO, set
Output Ripple and Noise
Measured across 10µF Tantalum, 1µF
Ceramic,
RMS (5 Hz to 20 MHz bandwidth)
Peak-to-peak (5 Hz to 20 MHz bandwidth)
All
All
7
25
15
30
mVrms
mVp-p
Output Current All IO 10 A
Output Current-limit Inception
(VO = 90% of VO, set)
All IO 17 A
Output Short-circuit Current (Average)
VO = 0.25 V
All IO 3 A
Efficiency
(VI = VIN, nom; IO = IO, max), TA = 25 °C
AXH010A0S0R9
AXH010A0S1R0
AXH010A0P
AXH010A0M
AXH010A0Y
AXH010A0D
AXH010A0G
AXH010A0F
η
η
η
η
η
η
η
η
83
85
86
88
90
91
92
95
%
%
%
%
%
%
%
%
Switching Frequency All fsw 300 kHz
Parameter Min Typ Max Unit
Calculated MTBF (IO = 100% of IO, max TA = 25 °C) 10,240,000 Hours
Weight 6.5(0.23) 7.5(0.27) g (oz.)

AXH010A0P5Z

Mfr. #:
Manufacturer:
ABB Embedded Power
Description:
Non-Isolated DC/DC Converters
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union