11
■ Setting of the emulator-dedicated power supply
Using the emulator-dedicated power supply setting jumper on the adapter board, set the tool interface
power supply on the evaluation MCU to operate with the user power supply (UV
CC1) or the devel-
opment tool power supply (+5 V).
On an evaluation MCU that has an emulator-dedicated power supply, the development tool power
supply must supply power to the evaluation MCU as a tool interface power supply.
For an evaluation MCU that has an emulator-dedicated power supply, set the development tool power
supply (+5 V). For an evaluation MCU that does not have a emulator-dedicated power supply, set the
user power supply (UV
CC1).
For details on an evaluation MCU with a emulator-dedicated power supply, see the Evaluation MCU
hardware manual of the relevant product, or contact the sales or support representative.
Figure 13 shows the emulator-dedicated power supply setting jumper. Table 5 lists the settings of the
jumper.
Figure 13 Emulator-dedicated power supply setting jumper
Table 5 Settings of the emulator-dedicated power supply setting jumper
Emulator-dedicated power supply pin Setting of VCC SEL (S1)
Available TOOL VCC: B-C connected (+5 V)
Not available TOOL VCC: A-B connected (UV
CC1)
VCC SELS1
CB A
TOOL VCC
*
1
P0V
*
2
P1V
*
3
*1 : Emulator-dedicated power supply setting jumper
*2 : Power supply setting jumper of user port 0 (For details, see "■ User port pow-
er supply setting".)
*3 : Power supply setting jumper of user port 1 (For details, see "■ User port pow-
er supply setting".)