PDUMH30HVATNET

Management Interface
The management interface for this PDU model is transitioning to a new technology platform. The new
interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place of the
round ENVIROSENSE port. For managing the units containing the round port, Tripp Lite recommends
using the PowerAlert Console Launcher rather than a web browser. This application enables local access
of the PDU using a self-contained, compatible Java Runtime Environment version. The Console Launcher
can be downloaded for free; click the above link or go to the Management Solutions / Utilities page. Units
with the new interface work will with most current web browsers.
5.76kW Single-Phase ATS/Switched PDU, LX
Platform Interface, 208/240V (16 C13, 2 C19 & 1
L6-30R) 2 L6-30P Inputs, 2U Rack-Mount, TAA
MODEL NUMBER: PDUMH30HVATNET
Description
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded
network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power
sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input
cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the
secondary power source until the primary input is restored and stable. Highly reliable solid-state switching
between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include
individually controllable output receptacles and built-in network interface. Super-fast switchover between
primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any
two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant
power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a
single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system.
In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with
zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a
two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even
separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power
quality on both input sources to prevent transfer to the secondary source when unavailable or of lower
quality than the primary source. Front input LED's display primary or secondary power availability. Built-in
LX Platform network management interface card. The Java-free LX Platform HTML5-based network
interface enables full remote access for PDU status monitoring and
email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing
for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately)
provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS,
SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Features
208/240V 30A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 24A continuous)
Highlights
Single phase 30A 208/240V
Auto Transfer Switch / ATS PDU
with Solid State Switching
Separate primary & secondary
inputs enable redundant-power
option for non-redundant
network devices
LX Platform Network Interface
2U rackmount, 2 L6-30P inputs,
19 switched outlets (16 C13, 2
C19, 1 L6-30R)
Individually switched outlets,
network interface and visual
current, voltage and
environmental monitoring
Compliant with the Federal
Trade Agreements Act (TAA) for
GSA Schedule purchases
Package Includes
2U ATS PDU
Rackmount installation brackets
Cable retention plates and cable
ties
User manual
1 / 4
Specifications
ATS features provide redundant power for critical network equipment with a single input power cord
2 digit display reports output power consumption in amps
2U horizontal rackmount form factor; 12.5 in. / 31.8 cm depth
19 built-in switched outlets (16 C13, 2 C19 & 1 L6-30R)
Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and
SECONDARY inputs
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails
or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable
until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS
and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-
UPS environment, the primary input cable must be supported by an online UPS with zero transfer time
similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate
out of phase utility power grid feeds are fully supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the
secondary source when unavailable or of lower quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 2-6 milliseconds
Switched outlets and ethernet interface supports individual outlet control on a real-time or
programmable basis and user-specified alarm notification thresholds for all reported site power
conditions
LX Platform interface allows full remote access for power monitoring with email notifications via secure
web browser, SNMP, telnet or SSH
Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring
capabilities
Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first
energized to prevent inrush-related equipment interaction on startup
Front panel LEDs confirm power availability on both input lines and for each output receptacle
Included cord retention brackets keep vital network equipment plugged in and continuously powered
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
OVERVIEW
UPC Code 037332159601
PDU Type Auto-Transfer Switch; Switched
OUTPUT
2 / 4
Output Capacity Details 5.76kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A); 24A max per L6-30R
outlet; 16A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) C13; (2) C19; (1) L6-30R
Output Nominal Voltage 200; 208; 240
Overload Protection Includes two 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19); Breaker 2
controls the lower row of outlets (8 C13, 1 C19); L6-30R outlet is unbreakered
Customized Load Management
Receptacles
Each outlet is individually controllable via remote interface
INPUT
PDU Input Voltage 200; 208; 240
Recommended Electrical Service 30A 208/240V
Maximum Input Amps 30.0
Maximum Input Amps Details Agency rated to 24A continuous
PDU Plug Type (2) NEMA L6-30P
Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.) 10
Input Cord Length (m) 3.05
Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports output amps in 4 separately metered loading segments (BANK 1: Outlets #1-9; BANK 2:
Outlets #10-18; BANK 3: Outlet #19), whole-PDU output kW load level and input voltage on primary and secondary
input lines
Front Panel LEDs 19 LEDs display power on/off status for each outlet, plus 2 LEDs for power status on Primary and Secondary input
connection and three additional LEDs to label the displayed numeric value as Amps, kW or Voltage
Switches ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output and input
voltage (primary, secondary)
Current Measurement Accuracy
(Amps)
+/-1%
Voltage Measurement Accuracy
(Volts)
+/-1%
Power Measurement Accuracy
(Watts)
+/-1%
PHYSICAL
Minimum Required Rack Depth
(inches)
16
Minimum Required Rack Depth (cm) 40.64
Shipping Dimensions (hwd / in.) 7.80 x 16.80 x 19.90
Shipping Dimensions (hwd / cm) 19.81 x 42.67 x 50.55
3 / 4

PDUMH30HVATNET

Mfr. #:
Manufacturer:
Tripp Lite
Description:
Power Outlet Strips Tripp Lite PDU Switched ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet