MPX5500DP

MPX5500
Rev 7, 09/2009
Freescale Semiconductor
© Freescale Semiconductor, Inc., 2005-2009. All rights reserved.
Pressure
+
Integrated Silicon Pressure Sensor
On-Chip Signal Conditioned,
Temperature Compensated and
Calibrated
The MPX5500 series piezoresistive transducer is a state-of-the-art
monolithic silicon pressure sensor designed for a wide range of applications,
but particularly those employing a microcontroller or microprocessor with A/D
inputs. This patented, single element transducer combines advanced
micromachining techniques, thin-film metallization, and bipolar processing to
provide an accurate, high level analog output signal that is proportional to the
applied pressure.
Features
2.5% Maximum Error over 0° to 85°C
Ideally suited for Microprocessor or Microcontroller-Based Systems
Patented Silicon Shear Stress Strain Gauge
Durable Epoxy Unibody Element
Available in Differential and Gauge Configurations
ORDERING INFORMATION
Device Name
Case
No.
# of Ports Pressure Type
Device
Marking
None Single Dual Gauge Differential Absolute
Unibody Package (MPX5500 Series)
MPX5500D
867 MPX5500D
MPX5500DP
867C MPX5500DP
MPX5500
Series
0 to 500 kPa (0 to 72.5 psi)
0.2 to 4.7 V Output
MPX5500D
CASE 867-08
MPX5500DP
CASE 867C-05
UNIBODY PACKAGES
MPX5500
Sensors
2 Freescale Semiconductor
Pressure
Operating Characteristics
Table 1. Operating Characteristics (V
S
= 5.0 Vdc, T
A
= 25°C unless otherwise noted, P1 > P2. Decoupling circuit shown in
Figure 4. required to meet electrical specifications.)
Characteristic Symbol Min Typ Max Unit
Pressure Range
(1)
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
P
OP
0—500kPa
Supply Voltage
(2)
2. Device is ratiometric within this specified excitation range.
V
S
4.75 5.0 5.25 Vdc
Supply Current I
O
—7.010mAdc
Zero Pressure Offset
(3)
(0 to 85°C)
3. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
V
off
0.088 0.20 0.313 Vdc
Full Scale Output
(4)
(0 to 85°C)
4. Full Scale Output (V
FSO
) is defined as the output voltage at the maximum or full rated pressure.
V
FSO
4.587 4.70 4.813 Vdc
Full Scale Span
(5)
(0 to 85°C)
5. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
V
FSS
—4.50—Vdc
Accuracy
(6)
(0 to 85°C)
6. Accuracy (error budget) consists of the following:
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis:Output deviation at any temperature within the operating temperature range, after the temperature is cycled to and
from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the minimum or
maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0° to 85°C, relative to 25°C.
TcOffset:Output deviation with minimum rated pressure applied, over the temperature range of 0° to 85°C, relative to 25°C.
Variation from Nominal:The variation from nominal values, for Offset or Full Scale Span, as a percent of V
FSS
, at 25°C.
———±2.5 %V
FSS
Sensitivity V/P 9.0 mV/kPa
Response Time
(7)
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
specified step change in pressure.
t
R
—1.0—ms
Output Source Current at Full Scale Output I
O+
—0.1—mAdc
Warm-Up Time
(8)
8. Warm-up Time is defined as the time required for the device to meet the specified output voltage after the pressure has been stabilized.
——20ms
MPX5500
Sensors
Freescale Semiconductor 3
Pressure
Maximum Ratings
Figure 1 shows a block diagram of the internal circuitry integrated on a pressure sensor chip.
Figure 1. Fully Integrated Pressure Sensor Schematic
Table 2. Maximum Ratings
(1)
1. Maximum Ratings apply to Case 867 only. Extended exposure at the specified limits may cause permanent damage or degradation to the
device.
Rating Symbol Value Unit
Maximum Pressure
(2)
(P2 1 Atmosphere)
2. This sensor is designed for applications where P1 is always greater than, or equal to P2. P2 maximum is 500 kPa.
P1
max
2000 kPa
Storage Temperature T
stg
-40 to +125 °C
Operating Temperature T
A
-40 to +125 °C
Sensing
Element
Thin Film
Temperature
Compensation
and
Gain Stage #1
Gain Stage #2
and
Ground
Reference
Shift Circuitry
V
S
V
out
GND
Pins 4, 5, and 6 are NO CONNECTS for
Unibody Package.
1
3
2

MPX5500DP

Mfr. #:
Manufacturer:
NXP Semiconductors
Description:
IC SENSOR PRESS GAUGE 75PSI RANG
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet