263
4-φ4.3±0.3
25±0.5
71.5±0.3
71.5±0.3
80±0.5
80±0.5
(10)
(4)
(4)
風吹出方向
回転方向
リード線
AWG24
UL1007
取付用穴
+30
300 0
φ90
71.5±0.3
4-φ4.5
78.5
71.5±0.3
78.5
80
mm sq.
■ Dimensions
(unit: mm)
Splash Proof Fan
80×80×25mm 〔Mass:120g〕
San Ace 80WS
IP 54
■ General Specications
・
Material
……………………
Frame: Plastics (Flammability: UL94V-0),
Impeller: Plastics (Flammability: UL94V-1)
・
Expected Life
……………
Refer to specications (Indoor, L10:Survival rate: 90% at 60
℃
,
rated voltage, and continuously run in a free air state)
・
Lead Wire
…………………⊕
red
⊖
black or blue
Sensor
yellow
・
Storage Temperature
…-
30
℃
to
+
70
℃(
Non-condensing
)
■ Specications
The following nos. have pulse sensors and ribs. For ribless, append "1" to the model no.
Model No.
Rated Voltage
Operating Voltage Range
Rated Current
Rated Input Rated Speed Max. Airow
Max. Static Pressure
SPL
Operating Temperature
Expected Life
[V] [V] [A] [W] [min
-1
]
[
m³/min
]
[CFM] [Pa] [inchH
²
O] [dB(A)] [℃] [h]
9WS0812H401
12 10.2 to 13.8
0.16 1.92 3,100 0.94 33.2 45.1 0.181 32
- 20 to + 70
40,000/60
℃
9WS0812F401
0.13 1.56 2,700 0.83 29.3 34.3 0.138 28
9WS0812M401
0.1 1.2 2,200 0.65 23.0 23.5 0.094 23
9WS0824H401
24 20.4 to 27.6
0.09 2.16 3,100 0.94 33.2 45.1 0.181 32
9WS0824F401
0.07 1.68 2,700 0.83 29.3 34.3 0.138 28
9WS0824M401
0.05 1.2 2,200 0.65 23.0 23.5 0.094 23
Inlet side, Outlet side
■ Reference Dimensions of Mounting Holes and Vent Opening
(unit: mm)
Rotating Direction
Airow Direction
Mounting Hole
Lead Wire
(
With ribs
)
Other sensor specications are available as options. Please refer to the index (pp. 512 to 513).
9WS
type