4
PS8103
ELECTRICAL CHARACTERISTICS (TA = 25°C)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Diode Forward Voltage VF IF = 16 mA 1.2 1.5 V
Reverse Current IR VR = 3 V 10
µ
A
Terminal Capacitance Ct V = 0 V, f = 1 MHz 30 pF
Detector High Level Output Current IOH (1) IF = 0 mA, VCC = VO = 5.5 V 7 500 nA
High Level Output Current IOH (2) IF = 0 mA, VCC = VO = 15 V 100
µ
A
Low Level Output Voltage VOL IF = 16 mA, VCC = 4.5 V, IOL = 1.1 mA 0.1 0.4 V
High Level Supply Current ICCH IF = 0 mA, VO = open, VCC = 15 V 0.01 1
µ
A
Low Level Supply Current ICCL IF = 16 mA, VO = open, VCC = 15 V 150 800
Coupled Current Transfer Ratio (IC/IF)
*1
CTR IF = 16 mA, VCC = 4.5 V, VO = 0.4 V 10 23 30 %
Isolation Resistance RI-O VI-O = 1 kVDC, RH = 40 to 60% 10
11
Ω
Isolation Capacitance CI-O V = 0 V, f = 1 MHz 0.4 pF
Propagation Delay Time
(H → L)
*2
tPHL IF = 16 mA, VCC = 5 V, RL = 4.1 kΩ,
C
L = 15 pF
1 5
µ
s
Propagation Delay Time
(L → H)
*2
tPLH 2 5
Propagation Delay Time
(H → L)
*2
tPHL IF = 16 mA, VCC = 5 V, RL = 20 kΩ,
C
L = 15 pF
1 15
Propagation Delay Time
(L → H)
*2
tPLH 7 15
*1 CTR rank
L : 15 to 30 (%)
N : 10 to 30 (%)
*2 Test circuit for propagation delay time
Pulse input (I
F
)
47 Ω
(Pulse width = 100 s,
Duty cycle = 1/10)
µ
R
L
= 4.1/20 kΩ
V
O
(Monitor)
V
CC
= 5 V
Input
(Monitor)
0.1 F
µ
C
L
= 15 pF
Input
Output
50%
1.5 V
5 V
V
OL
t
PHL
t
PLH
C
L includes probe and stray wiring capacitance.
USAGE CAUTIONS
1. This product is weak for static electricity by designed with high-speed integrated circuit so protect against static
electricity when handling.
2. By-pass capacitor of 0.1
µ
F is used between VCC and GND near device. Also, ensure that the distance between
the leads of the photocoupler and capacitor is no more than 10 mm.
3. Avoid storage at a high temperature and high humidity.