Silicon Pressure Sensors
Ultra Low Pressure Sensing
DC Series
ELECTRICAL SPECIFICATIONS
Ouput
Pressure
Reference
Excitation
(Vdc)
Offset
(1)
Voltage (Vdc)
Output Span
(Vdc)
Supply
Current (max.)
Output
Source
Current (max.)
Output Sink
Current @
null (max.)
Gage 5 ±0.1 0.25 4 4 mA 2.0 mA 20 μA
C4 Ratiometric
Differential 5 ±0.1 2.25 ±2 4 mA 2.0 mA 20 μA
Gage 7 to 16 0.25 4 8 mA 2.0 mA 20 μA
R4 Regulated
Differential 7 to 16 2.25 ±2 8 mA 2.0 mA 20 μA
Gage 7 to 16 0.25 5 8 mA 2.0 mA 20 μA
R5 Regulated
Differential 7 to 16 3.5 ±2.5 8 mA 2.0 mA 20 μA
PERFORMANCE SPECIFICATIONS
(2)
Pressure
Ranges
Overpressure
Offset
Position
Sensitivity
Total Error
(Typical)
Total Error
(3)
(Max.)
Accuracy
(4)
±0.5 in H2O 100 in H2O ±10 mV ±2.0 % ±3.0 % ±0.25 %
1 in H2O 100 in H2O ±10 mV ±2.0 % ±3.0 % ±0.25 %
2.5 mBar 250 mBar ±10 mV ±2.0 % ±3.0 % ±0.25 %
2 in H2O 100 in H2O ±10 mV ±1.5 % ±2.5 % ±0.25 %
5 mBar 250 mBar ±10 mV ±1.5 % ±2.5 % ±0.25 %
2.5 in H2O 100 in H2O ±10 mV ±1.5 % ±2.5 % ±0.25 %
5 in H2O 150 in H2O ±5 mV ±1.0 % ±2.0 % ±0.25 %
10 mBar 375 mBar ±5 mV ±1.0 % ±2.0 % ±0.25 %
10 in H2O 150 in H2O ±1 mV ±1.0 % ±2.0 % ±0.25 %
25 mBar 375 mBar ±1 mV ±1.0 % ±2.0 % ±0.25 %
20 in H2O 300 in H2O ±1 mV ±1.0 % ±2.0 % ±0.25 %
50 mBar 750 mBar ±1 mV ±1.0 % ±2.0 % ±0.25 %
30 in H2O 450 in H2O ±1 mV ±1.0 % ±2.0 % ±0.25 %
75 mBar 1125 mBar ±1 mV ±1.0 % ±2.0 % ±0.25 %
140 cm H2O 1125 cm H2O ±1 mV ±1.0 % ±2.0 % ±0.25 %
Note 1: Offset voltage and output span are nominal
Note 2: All specifications are relative to readings taken at 25 °C [77 °F] and at rated excitation unless otherwise specified.
Note 3: Percentage of Full Scale Includes: zero calibration, span calibration, temperature effect on zero and span, non-
linearity, hysteresis, repeatability and stability over the compensated temperature range.
Note 4: Percentage of Best Fit Straight Line Includes: non-linearity, hysteresis, and repeatability.
Material in Contact with Media
Silicon diaphragm, glass filled nylon, silicone, and alumina
ceramic.
Compensated Temperature Range 0 °C to 50 °C [32 °F to 170 °F]
Operating Temperature Range -25 °C to 85 °C [-13 °F to 185 °F]
Storage Temperature -40 °C to 125 °C [-40 °F to 257 °F]
2 Honeywell • Sensing and Control