Derating-Graph
(Ambient Temperature)
Selection Guide
7.5 Watt
DIP24 & SMD
Single & Dual
Output
●
7.5W DIP24 Package
●
1KVDC, 2KVDC and 3kVDC Isolation Options
● Approved for Medical Applications (/H)
●
UL and EN Safety Approvals
●
Continuous Short Circuit Protection
(power limiting)
●
5 Side Shielded Metal Case
●
Full SMD design
●
2 Case Style Options
●
Remote Pin Option
●
Efficiency to 86%
Features
Regulated
Converters
Part Input Output Output Efficiency Max
Number Voltage Voltage Current Capacitive
(VDC) (VDC) (mA) (%) Load
(1)
REC7.5-xx3.3SRW/H*/A/M 9-18, 18-36, 36-72 3.3 1800 78 6800µF
REC7.5-xx05SRW/H*/A/M 9-18, 18-36, 36-72 5 1500 79-82 6800µF
REC7.5-xx09SRW/H*/A/M 9-18, 18-36, 36-72 9 833 81-84 6800µF
REC7.5-xx12SRW/H*/A/M 9-18, 18-36, 36-72 12 625 82-85 6800µF
REC7.5-xx15SRW/H*/A/M 9-18, 18-36, 36-72 15 500 83-86 6800µF
REC7.5-xx05DRW/H*/A/M 9-18, 18-36, 36-72 ±5 ±750 79-82 ±2200µF
REC7.5-xx09DRW/H*/A/M 9-18, 18-36, 36-72 ±9 ±417 81-84 ±2200µF
REC7.5-xx12DRW/H*/A/M 9-18, 18-36, 36-72 ±12 ±312 82-85 ±2200µF
REC7.5-xx15DRW/H*/A/M 9-18, 18-36, 36-72 ±15 ±250 83-86 ±2200µF
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-72Vin = 48
* add suffix /H1 for 1kVDC Isolation, /H2 for 2kVDC isolation or /H3
for 3kVDC Isolation (not available in H3/A/M/SMD combination)
* add suffix “/SMD” for SMD package, e.g. REC7.5-2405DRW/H1/A/M/SMD
* add suffix “/CTRL” for Remote Pin option
* add suffix „-R“ for Tape and Reel Packaging (only for SMD type available)
e.g. REC7.5-2405DRW/H1/A/M/SMD/CTRL-R
no plastic case is available for REC7.5
Description
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
The REC7.5-xxxxSRW/DRW-series offer single and dual regulated outputs in a DIP24 package
with 1kV, 2kV or 3kV options and are suitable for higher power industrial or medical
applications. Remote on/off control is possible with the /CTRL option and SMD pinning is
offered with the /SMD option. The converters can deliver 140% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents.
Refer to Application Notes
E-358085
RoHS
2011/65/EU
6/6
Dual
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 0/2015 E-157www.recom-power.com