Rated currents from 3 to 6 A
Exceptional differential and common-mode
attenuation
UL-rated materials
Optional medical versions (B type)
Technical specifications
Maximum continuous operating voltage 250 VAC, 50/60 Hz
Operating frequency dc to 400 Hz
Rated currents 3 to 6 A @ 40 °C max.
High potential test voltage P –> PE 2000 VAC for 2 sec
P –> N 1100 VDC for 2 sec
Temperature range (operation and storage) -25 °C to +100 °C (25/100/21)
Flammability corresponding to UL 94 V-2 or better
Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF @ 40°C/230V (Mil-HB-217F) 2,400,000 hours
Approvals
Features and benefits
FN 2360 filters are designed for easy and fast chassis
mounting
FN 2010 filters have a perfect performance/size ratio
All filters provide a very high differential and
common-mode attenuation performance, based on
chokes with high saturation resistance and excellent
thermal behavior
Faston terminal connection with additionl spade
solder possibility
Optional medical versions (B type)
Custom-specific versions on request