250W Constant Current Mode LED Driver
HLG-240H-C series
File Name:HLG-240H-C-SPEC 2018-05-29
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
SET UP TIME
Note.4
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal
potentiometer (A/AB type only)
1000ms/115VAC, or 500ms/230VAC
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
2.5A / 115VAC 1.3A / 230VAC 1.1A / 277VAC
<0.75mA / 277VAC
Compliance to EN55015, EN61000-3-2 Class C (@ load 50%) ; EN61000-3-3≧ ,EAC TP TC 020,GB17743 and GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level ( )surge immunity Line-Earth 4KV, Line-Line 2KV
,EAC TP TC 020
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
℃
±℃ ℃
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750 , 61347-1, 61347-2-13, EN62384 independent(type”HL”) EN/AS/NZS EN/AS/NZS ;CSA C22.2 No. 250.13-12;
GB19510.1,GB19510.14; , EAC TP TC 004 approvedIP65 or IP67
180K hrs min. MIL-HDBK-217F (25 )
℃
244.2*68*38.8mm (L*W*H)
Shut down and latch off o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
375 ~ 410V
250 ~ 275V 150 ~ 165V
188 ~ 206V 125 ~ 137V
93.5%
93.5%
94%94% 93.5%
350 ~ 700mA 525 ~ 1050mA 700 ~ 1400mA 875 ~ 1750mA 1050 ~ 2100mA
700mA
HLG-240H-C700 HLG-240H-C1050 HLG-240H-C1400 HLG-240H-C1750 HLG-240H-C2100
178 ~ 357V
1050mA
119 ~ 238V
1750mA
71 ~ 143V
249.9W
249.9W
250.25W
2100mA
59 ~ 119V
249.9W
1400mA
89 ~ 179V
250.6W
EMC IMMUNITY
EMC EMISSION
COLD START 75A(t =700 s measured at 50% I ) at 230VAC;
width peak Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
CONSTANT CURRENT REGION
Note.2
PACKING
1.3Kg; 12pcs/16.6Kg/0.84CUFT
NOTE
μ
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
CURRENT TOLERANCE ±5%
OPEN CIRCUIT VOLTAGE (max.)
360V 241V 182V 146V 122V
CURRENT RIPPLE 5.0% max. @rated current
PF 0.9 / VAC, PF 0.9 /2 VAC full load≧≧≧8 115 5 30 , PF 0.92/277VAC @
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
THD< 20% (@ load 50% /115VAC, 230VAC; @ load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently
connected to the mains.
7. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.℃
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
WORKING TEMP.
Tcase=-40 ~ +90 (Refer to "Derating Curve")℃
MAX. CASE TEMP.
Tcase=+90℃