DS1340
I
2
C RTC with Trickle Charger
______________________________________________________________________________________ 15
Revision History
REVISION
NUMBER
REVISION
DATE
DESCRIPTION
PAGES
CHANGED
0 6/03
Initial release. —
Changed “2-wire” to “I
2
C” throughout the data sheet.
All
Added UL recognition info bullet to the Features section and to the V
BACKUP
pin
description.
1, 6
Added the “I/O Capacitance (SCL, SDA)” parameter (C
I/O
) to the AC Electrical
Characteristics table.
2
1 7/04
Added “SDA, SCL” and “V
CC
= 0V” to the “Supply Voltage, Pullup (FT/OUT)” parameter
and changed the symbol from “V
IH
” to “V
PU
” in the Recommended DC Operating
Conditions table; in the DC Electrical Characteristics table, changed the “Oscillator
Current” parameter to “V
BACKUP
Current.”
3
Added the integrated-crystal and lead-free packages to the Ordering Information table;
added the integrated-crystal packages to the Features, Pin Configurations, Pin
Description.
1, 6
In Table 1, added increased crystal ESR with increased supply minimum voltage
requirement.
6
Added the DS1340C Only section. 7
Updated Figure 5 to also show the “C Version” crystal. 7
Added the Handling, PC Board Layout, and Assembly section. 12
2 12/04
Added the integrated-crystal package Theta-JA and Theta-JC information to the
Thermal Information section.
13
3 11/05 Updated the Ordering Information table to correct lead-free/RoHS packages. 1
In the General Description section, indicated that the time and date function continues
while powered by V
BACKUP
.
1
Updated the Typical Operating Circuit by removing pin numbers and adding a bypass
capacitor.
1
In the Pin Description, updated the V
BACKUP
description to indicate that no diodes
should be placed between the battery and pin and added the UL link; changed the
V
CC
description.
6
Added the Power Control section and new Table 1. 6
In the Handling, PC Board Layout, and Assembly section, added solder reflow
information for the RoHS SO package.
13
4 3/06
Added Package Information table. 14
Removed leaded part numbers from the Ordering Information table. 1
Removed the t
RPU
parameter and RST waveform from Figure 2. Replaced t
RST
with t
REC
.
5
In the Typical Operating Characteristics section, updated/changed the “FT vs.
V
BACKUP
” graph to “OSCILLATOR FREQUENCY vs. SUPPLY VOLTAGE (FT x 64).”
5
In the Pin Description, added pullup voltage information to the SDA, SCL, and FT/OUT
descriptions.
6
Updated Figure 5. 8
In the Clock and Calendar section, added text explaining the use of EOSC to halt the
oscillator.
9
5 8/08
Replaced Figure 7 with an updated version; changed Figures 8 and 9 and added
Figure 10 with more comprehensive I
2
C figures.
13